Research on corrosion rate assessment of buried pipelines under dynamic metro stray current

Yanxia Du, Huimin Qin, Jie Liu, D. Tang
{"title":"Research on corrosion rate assessment of buried pipelines under dynamic metro stray current","authors":"Yanxia Du, Huimin Qin, Jie Liu, D. Tang","doi":"10.1002/maco.202012082","DOIUrl":null,"url":null,"abstract":"To provide a reference for the evaluation of corrosion rate under dynamic metro stray current, both simulated experiments in laboratory and coupon tests in the field were conducted to explore the corrosion behavior and the relationship between corrosion rates and dynamic DC interference parameters of buried pipelines. The results show that the dynamic period has a significant influence on the corrosion rate and the ratio of actual corrosion rate to the theoretical corrosion rate. The statistical data of pipe to soil potentials or current densities of coupons electrically connected to pipelines obtained from the field in many cities of China show that the dynamic fluctuation periods under metro stray current are within the range of 0–300 s, among which the majority of fluctuation periods distribute from 50 to 200 s. The dynamic fluctuation of pipe to soil potentials and current densities of coupons exhibits symmetric or asymmetric characteristics. Under the situation of symmetric positive and negative current density, the ratio of the actual corrosion rate to the theoretical corrosion rate ranges from about 4% to 22% under the typical dynamic periods range from 50 to 200 s based on the simulated experiments results in the laboratory. Besides, two corrosion rate assessment methods, including the positive shifting and time ratios of off‐potentials and symmetrical or asymmetric characteristics of DC current density of coupons were proposed. In addition, the evaluation of the on‐potential criteria to assess the corrosion risk of time‐variant anodic interference was also discussed in the paper.","PeriodicalId":18223,"journal":{"name":"Materials and Corrosion","volume":"144 1","pages":"1038 - 1050"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials and Corrosion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/maco.202012082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

To provide a reference for the evaluation of corrosion rate under dynamic metro stray current, both simulated experiments in laboratory and coupon tests in the field were conducted to explore the corrosion behavior and the relationship between corrosion rates and dynamic DC interference parameters of buried pipelines. The results show that the dynamic period has a significant influence on the corrosion rate and the ratio of actual corrosion rate to the theoretical corrosion rate. The statistical data of pipe to soil potentials or current densities of coupons electrically connected to pipelines obtained from the field in many cities of China show that the dynamic fluctuation periods under metro stray current are within the range of 0–300 s, among which the majority of fluctuation periods distribute from 50 to 200 s. The dynamic fluctuation of pipe to soil potentials and current densities of coupons exhibits symmetric or asymmetric characteristics. Under the situation of symmetric positive and negative current density, the ratio of the actual corrosion rate to the theoretical corrosion rate ranges from about 4% to 22% under the typical dynamic periods range from 50 to 200 s based on the simulated experiments results in the laboratory. Besides, two corrosion rate assessment methods, including the positive shifting and time ratios of off‐potentials and symmetrical or asymmetric characteristics of DC current density of coupons were proposed. In addition, the evaluation of the on‐potential criteria to assess the corrosion risk of time‐variant anodic interference was also discussed in the paper.
动态地铁杂散电流作用下埋地管道腐蚀速率评估研究
为了为评价动态地铁杂散电流作用下的腐蚀速率提供参考,通过室内模拟试验和现场试验两种方法,探讨了埋地管道的腐蚀行为以及腐蚀速率与动态直流干扰参数的关系。结果表明,动态周期对腐蚀速率和实际腐蚀速率与理论腐蚀速率之比有显著影响。根据国内多个城市现场获得的管道对土电位或管道接电板电流密度的统计数据表明,地铁杂散电流作用下的动态波动周期在0 ~ 300 s之间,其中大部分波动周期分布在50 ~ 200 s之间。管道对土壤电位的动态波动和管道电流密度的动态波动表现出对称或不对称特征。在正负电流密度对称的情况下,根据室内模拟实验结果,在典型动态周期为50 ~ 200 s的情况下,实际腐蚀速率与理论腐蚀速率之比约为4% ~ 22%。此外,还提出了两种腐蚀速率的评估方法,包括断电位的正移比和时间比以及电极直流电流密度的对称或不对称特性。此外,本文还讨论了时变阳极干扰腐蚀风险评估的电位标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书