Determination of zirconium with Xylenol Orange by flow injection spectrophotometry: application to eluates from technetium-99m generators

K. Grudpan, Mayuree Utamong, C. Taylor
{"title":"Determination of zirconium with Xylenol Orange by flow injection spectrophotometry: application to eluates from technetium-99m generators","authors":"K. Grudpan, Mayuree Utamong, C. Taylor","doi":"10.1039/A708836A","DOIUrl":null,"url":null,"abstract":"A procedure for the determination of zirconium using Xylenol Orange has been developed from a conventional spectrophotometric one. An acidic medium of sulfuric rather than perchloric acid has been adopted, to achieve a fast reaction rate and greater sensitivity. Under optimised conditions, calibrations were found to be linear over a range of at least up to 10 ppm of zirconium. The detection limit was found to be 0.08 ppm and precisions (RSDs) at the 1, 3 and 5 ppm levels were 2.3, 1.9 and 0.2%, respectively. The procedure has been shown to be free of interferences from species which are present in the eluate from a technetium-99m generator, and has been applied to the determination of zirconium in such an eluate.","PeriodicalId":7814,"journal":{"name":"Analytical Communications","volume":"40 1","pages":"107-108"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/A708836A","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A procedure for the determination of zirconium using Xylenol Orange has been developed from a conventional spectrophotometric one. An acidic medium of sulfuric rather than perchloric acid has been adopted, to achieve a fast reaction rate and greater sensitivity. Under optimised conditions, calibrations were found to be linear over a range of at least up to 10 ppm of zirconium. The detection limit was found to be 0.08 ppm and precisions (RSDs) at the 1, 3 and 5 ppm levels were 2.3, 1.9 and 0.2%, respectively. The procedure has been shown to be free of interferences from species which are present in the eluate from a technetium-99m generator, and has been applied to the determination of zirconium in such an eluate.
二甲酚橙流动注射分光光度法测定锆:在锝-99m发生器洗脱液中的应用
在常规分光光度法的基础上,建立了二甲酚橙法测定锆的新方法。采用硫酸作为酸性介质而不是高氯酸,以达到更快的反应速度和更高的灵敏度。在优化条件下,发现校准在至少10ppm锆的范围内是线性的。检出限为0.08 ppm,精密度(rsd)在1、3、5 ppm水平下分别为2.3、1.9、0.2%。该方法已被证明不受来自锝-99m发生器的洗脱液中存在的物质的干扰,并已应用于此类洗脱液中锆的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信