{"title":"Tanks Assurance and Endorsement Extension Strategy","authors":"Sahar Abdul-Karim Khattab, Marwa Sami Alsheebani","doi":"10.2118/207694-ms","DOIUrl":null,"url":null,"abstract":"\n The objective of this paper is to study various methods that can be implemented on existing or new tanks to achieve an extended endorsement period (e.g. 20 years plus) for Crude Oil Floating Roof Storage Tanks. This extended period is necessary in order to overcome anticipated future challenges in tank availability due to (i) increased production and loading, (ii) stretched major overhaul (MOH) duration due to unforeseen delays in MOH works, (iii) corrosion in bottom plates, etc. An extensive research based on international API Standard 653 \"Tank Inspection, Repair, Alteration, and Reconstruction\" was conducted to achieve this extended period. Initially, some COS tanks aspects were assessed based on API SPEC 653 (2014, Addendum 2, May 2020) to achieve this new Tanks Endorsement Vision, such as: (a) studying the currently applied Corrosion Protection Barriers to the COS tanks and their effectiveness to the endorsement period, (b) the adequacy of commonly applied Corrosion Protection Barriers with respect to the endorsement period, and (c) exploring possible enhancements on COS Tanks Corrosion Protection Barriers, and Monitoring systems to extend tanks endorsement period. Based on API SPEC 653 (2014, Addendum 2, May 2020), currently applied tank safeguards were found inadequate to achieve the 20 years plus tank endorsement period requirement. In order to extend tanks endorsement period, additional safeguards shall be implemented, with special attention to tank bottom plates (soil side), since corrosion problems are mostly exhibited in tank bottom plates from the soil/oil side. Multiple solutions for corrosion safeguards were explored and recommended as part of this study such as the installation of a CP system under COS tanks, as well as installation of a corrosion monitoring system, and performing routine in-service inspections for COS tanks (internal and external) as per API SPEC 653 (2014, Addendum 2, May 2020), etc. Overall, this paper provides an insight on the calculation method of tanks endorsement period, and possible tank corrosion safeguards and controls that can be implemented to extend the COS tanks endorsement period to at least 20 years. Results and recommendations studied in this paper will benefit the Oil and Gas Industry and help in overcoming future challenges.","PeriodicalId":10981,"journal":{"name":"Day 4 Thu, November 18, 2021","volume":"710 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 4 Thu, November 18, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/207694-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The objective of this paper is to study various methods that can be implemented on existing or new tanks to achieve an extended endorsement period (e.g. 20 years plus) for Crude Oil Floating Roof Storage Tanks. This extended period is necessary in order to overcome anticipated future challenges in tank availability due to (i) increased production and loading, (ii) stretched major overhaul (MOH) duration due to unforeseen delays in MOH works, (iii) corrosion in bottom plates, etc. An extensive research based on international API Standard 653 "Tank Inspection, Repair, Alteration, and Reconstruction" was conducted to achieve this extended period. Initially, some COS tanks aspects were assessed based on API SPEC 653 (2014, Addendum 2, May 2020) to achieve this new Tanks Endorsement Vision, such as: (a) studying the currently applied Corrosion Protection Barriers to the COS tanks and their effectiveness to the endorsement period, (b) the adequacy of commonly applied Corrosion Protection Barriers with respect to the endorsement period, and (c) exploring possible enhancements on COS Tanks Corrosion Protection Barriers, and Monitoring systems to extend tanks endorsement period. Based on API SPEC 653 (2014, Addendum 2, May 2020), currently applied tank safeguards were found inadequate to achieve the 20 years plus tank endorsement period requirement. In order to extend tanks endorsement period, additional safeguards shall be implemented, with special attention to tank bottom plates (soil side), since corrosion problems are mostly exhibited in tank bottom plates from the soil/oil side. Multiple solutions for corrosion safeguards were explored and recommended as part of this study such as the installation of a CP system under COS tanks, as well as installation of a corrosion monitoring system, and performing routine in-service inspections for COS tanks (internal and external) as per API SPEC 653 (2014, Addendum 2, May 2020), etc. Overall, this paper provides an insight on the calculation method of tanks endorsement period, and possible tank corrosion safeguards and controls that can be implemented to extend the COS tanks endorsement period to at least 20 years. Results and recommendations studied in this paper will benefit the Oil and Gas Industry and help in overcoming future challenges.