T. Folkestad, K. Mylvaganam, S.L. Bersaas, B. Ullebust
{"title":"Chirp excitation of ultrasonic probe for high-rangeability gas flowmetering","authors":"T. Folkestad, K. Mylvaganam, S.L. Bersaas, B. Ullebust","doi":"10.1109/ULTSYM.1989.67157","DOIUrl":null,"url":null,"abstract":"The adaptive signal processing based on pulse compression in conjunction with the ray rescue-angle orientation of the transducers is another important feature for achieving high-rangeability ultrasonic gas flowmetering. A technique for achieving the necessary broad bandwidth of the ultrasonic transducer, which has to be excited within a low-frequency band due to the increased absorption of ultrasound in gas with frequency, is described. A signal-processing system suitable for very low and high times-of-flight and their differences is also presented. Discussed is the use of a special filtering technique based on assessing the gradient of the time series (in ascending order) of times-of-flight which eliminates spurious times-of-flight observed in actual interrogations of the flow.<<ETX>>","PeriodicalId":89469,"journal":{"name":"Proceedings. IEEE Ultrasonics Symposium","volume":"17 1","pages":"1087-1092 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1989.67157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The adaptive signal processing based on pulse compression in conjunction with the ray rescue-angle orientation of the transducers is another important feature for achieving high-rangeability ultrasonic gas flowmetering. A technique for achieving the necessary broad bandwidth of the ultrasonic transducer, which has to be excited within a low-frequency band due to the increased absorption of ultrasound in gas with frequency, is described. A signal-processing system suitable for very low and high times-of-flight and their differences is also presented. Discussed is the use of a special filtering technique based on assessing the gradient of the time series (in ascending order) of times-of-flight which eliminates spurious times-of-flight observed in actual interrogations of the flow.<>