A hybrid PWM strategy combining modified space vector and triangle comparison methods

V. Blasko
{"title":"A hybrid PWM strategy combining modified space vector and triangle comparison methods","authors":"V. Blasko","doi":"10.1109/PESC.1996.548836","DOIUrl":null,"url":null,"abstract":"Classical space vector PWM with equal duration of application of zero state vectors V0 and V7 was modified. The time of application of vector V7 (and V0) was made changeable from 0 to 100% over the time T/sub 0/ for their combined application. The ratio of the duration of application of vector V0 vs. V7 can be kept constant or changed on a sample by sample basis with a significant impact on the characteristics of the PWM. Correlation between modified space vector and triangle comparison methods was established. It was proved in the paper that modified space vector PWM (with a classical space vector PWM as a special case) can be implemented as a triangle comparison method with added zero sequence. A new algorithm suitable for implementation of modified space vector method on digital or analog hardware for triangle comparison PWM was proposed. Because the algorithm combines the theory of space vector PWM with ease of implementation of a triangle comparison PWM it was named \"hybrid\" PWM (HPWM).","PeriodicalId":19979,"journal":{"name":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","volume":"193 1","pages":"1872-1878 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"116","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1996.548836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 116

Abstract

Classical space vector PWM with equal duration of application of zero state vectors V0 and V7 was modified. The time of application of vector V7 (and V0) was made changeable from 0 to 100% over the time T/sub 0/ for their combined application. The ratio of the duration of application of vector V0 vs. V7 can be kept constant or changed on a sample by sample basis with a significant impact on the characteristics of the PWM. Correlation between modified space vector and triangle comparison methods was established. It was proved in the paper that modified space vector PWM (with a classical space vector PWM as a special case) can be implemented as a triangle comparison method with added zero sequence. A new algorithm suitable for implementation of modified space vector method on digital or analog hardware for triangle comparison PWM was proposed. Because the algorithm combines the theory of space vector PWM with ease of implementation of a triangle comparison PWM it was named "hybrid" PWM (HPWM).
结合修正空间矢量和三角比较方法的混合PWM策略
对经典的零状态矢量V0和V7等持续时间的空间矢量PWM进行了改进。矢量V7(和V0)的应用时间在T/下标0/时间内从0到100%变化。矢量V0与V7的持续时间之比可以在一个采样的基础上保持恒定或改变,这对PWM的特性有重大影响。建立了修正空间矢量与三角比较方法的相关性。本文证明了修正空间矢量PWM(以经典空间矢量PWM为特例)可以采用加零序列的三角比较方法实现。提出了一种适用于在数字或模拟硬件上实现修正空间矢量法的三角比较PWM算法。由于该算法结合了空间矢量PWM的原理和三角比较PWM的易于实现性,因此被称为“混合型”PWM (HPWM)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信