{"title":"Les scanners: de la première à la dernière génération","authors":"B. Aubert","doi":"10.1016/S0222-0776(00)88245-0","DOIUrl":null,"url":null,"abstract":"<div><p>Since its introduction in 1971, computerized tomography has had an erior mous clinlcal impact with a constant technological evolution leading to an improvement of intrinsic performances [spatial resolution, contrest, etc), reduced acquisition times end to evolution of clinical protocols. All these advances were obtained by means of several new technological solutions which appeared around the third generation at the end of the 1970's. The latest main advancements concern: the use of solid-state detectors, which improve the detection efficiency, wireless data transmission and slip-ring garitry, allowing the continuous rotation of X-ray tube and detector to perform helical acquisition, high-power X-ray tubes, and hardware and software evolution to increase data volume and improve reconstruction time. So, today, it is possible to acquire data corresponding to a large anatomical volume (≈50 cm) in a short time (< 60 s). The more recent progresses concern the volumetric CT detector, the 0.5s rotation, the virtual endoscopy, and the functional imaging.</p></div><div><p>Depuis son apparition, en 1971, la tomographie assistée par ordinateur, ou scanographie, a révolutionné l'imagene radiologique par une évolution technologique permanente, conduisant à une amélloration des performances intrinséques (résolution spattale, contraste…), à une réduction des temps d`acquisition et à une évolùtion des protocoles d'exploration Tous ces progreès ont été obtenus grâce à de nouvelles solutions technologiques qui sont apparues autour de la géométrie d'acquisition, dite de troisième génération, (uniquement mouvement de rotation tube RX - détecteurs autour au patient) datant de la fin des années 1970 Si on se limite aux progrès les plus récents, on peut citer, ld développement de détecteurs solides qui ont amélioré l'efficacité de détection, la transmission sans tu des mesures et l'alimentation du tube RX par contacteurs qui ont permis la rotation continue du tube RX et des détecteurs à la base du mode hélicoïdal, les tubes avec anode à haute capacité thermique, les progrès en mattère d'iniormatique qui ont augmente le volume des données acquises et la vitesse de reconptruction Ainsi, à ce jour il est possible d'acouénr des données correspondant à ur large volume anatomique (≈ 50 cm) en moins de t minute Les progrès les plus récents concernent tes détecteurs multi-barrettes, les rotations de 0.5 s sur 360° l'endoscopie virtuelle, les études de perfusion et l'imagerie fonctionnelle</p></div>","PeriodicalId":101059,"journal":{"name":"RBM-News","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0222-0776(00)88245-0","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RBM-News","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0222077600882450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Since its introduction in 1971, computerized tomography has had an erior mous clinlcal impact with a constant technological evolution leading to an improvement of intrinsic performances [spatial resolution, contrest, etc), reduced acquisition times end to evolution of clinical protocols. All these advances were obtained by means of several new technological solutions which appeared around the third generation at the end of the 1970's. The latest main advancements concern: the use of solid-state detectors, which improve the detection efficiency, wireless data transmission and slip-ring garitry, allowing the continuous rotation of X-ray tube and detector to perform helical acquisition, high-power X-ray tubes, and hardware and software evolution to increase data volume and improve reconstruction time. So, today, it is possible to acquire data corresponding to a large anatomical volume (≈50 cm) in a short time (< 60 s). The more recent progresses concern the volumetric CT detector, the 0.5s rotation, the virtual endoscopy, and the functional imaging.
Depuis son apparition, en 1971, la tomographie assistée par ordinateur, ou scanographie, a révolutionné l'imagene radiologique par une évolution technologique permanente, conduisant à une amélloration des performances intrinséques (résolution spattale, contraste…), à une réduction des temps d`acquisition et à une évolùtion des protocoles d'exploration Tous ces progreès ont été obtenus grâce à de nouvelles solutions technologiques qui sont apparues autour de la géométrie d'acquisition, dite de troisième génération, (uniquement mouvement de rotation tube RX - détecteurs autour au patient) datant de la fin des années 1970 Si on se limite aux progrès les plus récents, on peut citer, ld développement de détecteurs solides qui ont amélioré l'efficacité de détection, la transmission sans tu des mesures et l'alimentation du tube RX par contacteurs qui ont permis la rotation continue du tube RX et des détecteurs à la base du mode hélicoïdal, les tubes avec anode à haute capacité thermique, les progrès en mattère d'iniormatique qui ont augmente le volume des données acquises et la vitesse de reconptruction Ainsi, à ce jour il est possible d'acouénr des données correspondant à ur large volume anatomique (≈ 50 cm) en moins de t minute Les progrès les plus récents concernent tes détecteurs multi-barrettes, les rotations de 0.5 s sur 360° l'endoscopie virtuelle, les études de perfusion et l'imagerie fonctionnelle