Stefan Mross, Peter Furst, S. Pierrat, T. Zimmermann, M. Kraft
{"title":"CMOS potentiostat and sensor with multilayer membrane for wide range measurements of glucose concentrations","authors":"Stefan Mross, Peter Furst, S. Pierrat, T. Zimmermann, M. Kraft","doi":"10.1109/ICSENS.2014.6985196","DOIUrl":null,"url":null,"abstract":"We report on an electrochemical measurement setup comprising a CMOS potentiostat and a glucose sensor with a two-layer membrane as the first steps towards the development of an integrated in-situ sensor system for bioreactors. The potentiostat has a chip size of 2.1 × 2.5 mm2 and a linear current range from -220 nA to 240 nA with a linearity of R2 = 0.9995. For wide range measurements of glucose concentrations in cell culture media, electrodes functionalized with the enzyme glucose oxidase were spin-coated with membranes made from polydimethylsiloxane (PDMS). With these membranes, glucose concentrations up to 400 mM were measured with a linear measurement range up to 100 mM. For interferent elimination, cellulose acetate membranes were employed.","PeriodicalId":13244,"journal":{"name":"IEEE SENSORS 2014 Proceedings","volume":"2 1","pages":"1096-1099"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE SENSORS 2014 Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2014.6985196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
We report on an electrochemical measurement setup comprising a CMOS potentiostat and a glucose sensor with a two-layer membrane as the first steps towards the development of an integrated in-situ sensor system for bioreactors. The potentiostat has a chip size of 2.1 × 2.5 mm2 and a linear current range from -220 nA to 240 nA with a linearity of R2 = 0.9995. For wide range measurements of glucose concentrations in cell culture media, electrodes functionalized with the enzyme glucose oxidase were spin-coated with membranes made from polydimethylsiloxane (PDMS). With these membranes, glucose concentrations up to 400 mM were measured with a linear measurement range up to 100 mM. For interferent elimination, cellulose acetate membranes were employed.