Study of the In Vitro Biodegradation Behavior of Mg–2.5Zn–xES Composite for Orthopedic Application

A. Bahgat, P. Okonkwo, G. Manoj, N. Alqahtani, R. Shakoor, A. Abdullah
{"title":"Study of the In Vitro Biodegradation Behavior of Mg–2.5Zn–xES Composite for Orthopedic Application","authors":"A. Bahgat, P. Okonkwo, G. Manoj, N. Alqahtani, R. Shakoor, A. Abdullah","doi":"10.29117/quarfe.2021.0097","DOIUrl":null,"url":null,"abstract":"Non-degradable steel and titanium implants used to replace defects of the locomotor system or fabricate vascular stents provide maximum stability but have too many drawbacks. However; the defects in oxide layer and the corrosive nature of physiological environment, the thermodynamic tendencies make the alloys susceptible to release of cationic species in the form of corrosion, which result in triggering various biological factors and compromises the mechanical integrity of the implanted materials. Currently, biodegradable magnesium alloys are considered as promising materials for creation of fixation devices in orthopedics and cardiovascular surgery. In this work, zinc (Zn) and eggshell (ES) reinforced biodegradable magnesium alloy (Mg–2.5Zn), and environment concise (eco) composite (Mg–2.5Zn–xES) was fabricated using disintegrated melt deposition (DMD) technique. In vitro experiments were conducted to explore the effect variable concentration of ES ( 3 and 7 wt%) on the biodegradation behavior of Mg–Zn alloy using simulated body fluid (SBF) at 37 ℃. The corrosion behavior of the Mg–2.5Zn–xES alloys was explored in SBF solution using different techniques such as weight loss measurement, hydrogen evolution, potentiodynamic polarization, electrochemical Impedance Spectroscopy (EIS). EIS revealed increased in vitro degradation of the biodegradable magnesium alloy, and ecofriendly composite as the percentage of ES reinforcement was increased. X-ray diffraction (XRD) was performed to observe the chemical composition of elements and reaction products present in the degraded samples after the corrosion process.","PeriodicalId":9295,"journal":{"name":"Building Resilience at Universities: Role of Innovation and Entrepreneurship","volume":"147 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Resilience at Universities: Role of Innovation and Entrepreneurship","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29117/quarfe.2021.0097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Non-degradable steel and titanium implants used to replace defects of the locomotor system or fabricate vascular stents provide maximum stability but have too many drawbacks. However; the defects in oxide layer and the corrosive nature of physiological environment, the thermodynamic tendencies make the alloys susceptible to release of cationic species in the form of corrosion, which result in triggering various biological factors and compromises the mechanical integrity of the implanted materials. Currently, biodegradable magnesium alloys are considered as promising materials for creation of fixation devices in orthopedics and cardiovascular surgery. In this work, zinc (Zn) and eggshell (ES) reinforced biodegradable magnesium alloy (Mg–2.5Zn), and environment concise (eco) composite (Mg–2.5Zn–xES) was fabricated using disintegrated melt deposition (DMD) technique. In vitro experiments were conducted to explore the effect variable concentration of ES ( 3 and 7 wt%) on the biodegradation behavior of Mg–Zn alloy using simulated body fluid (SBF) at 37 ℃. The corrosion behavior of the Mg–2.5Zn–xES alloys was explored in SBF solution using different techniques such as weight loss measurement, hydrogen evolution, potentiodynamic polarization, electrochemical Impedance Spectroscopy (EIS). EIS revealed increased in vitro degradation of the biodegradable magnesium alloy, and ecofriendly composite as the percentage of ES reinforcement was increased. X-ray diffraction (XRD) was performed to observe the chemical composition of elements and reaction products present in the degraded samples after the corrosion process.
骨科用Mg-2.5Zn-xES复合材料体外生物降解行为研究
不可降解的钢和钛植入物用于替代运动系统的缺陷或制造血管支架,提供了最大的稳定性,但有太多的缺点。然而;氧化层的缺陷和生理环境的腐蚀性、热力学倾向使合金容易以腐蚀的形式释放阳离子,从而引发各种生物因素,损害植入材料的机械完整性。目前,可生物降解镁合金被认为是制造骨科和心血管外科固定装置的有前途的材料。本文采用崩解熔融沉积(DMD)技术制备了锌(Zn)和蛋壳(ES)增强的可生物降解镁合金(Mg-2.5Zn)和环境简洁(eco)复合材料(Mg-2.5Zn - xes)。体外实验探讨了不同浓度ES (3 wt%和7 wt%)对37℃模拟体液(SBF)降解Mg-Zn合金行为的影响。采用失重测量、析氢、动电位极化、电化学阻抗谱(EIS)等方法研究Mg-2.5Zn-xES合金在SBF溶液中的腐蚀行为。随着ES增强率的增加,生物可降解镁合金和生态友好型复合材料的体外降解能力增强。通过x射线衍射(XRD)观察腐蚀后降解样品中元素和反应产物的化学组成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信