Medical ultrasonic probe using electrostrictive-ceramics/polymer composite

H. Takeuchi, H. Masuzawa, C. Nakaya, Y. Ito
{"title":"Medical ultrasonic probe using electrostrictive-ceramics/polymer composite","authors":"H. Takeuchi, H. Masuzawa, C. Nakaya, Y. Ito","doi":"10.1109/ULTSYM.1989.67077","DOIUrl":null,"url":null,"abstract":"A medical ultrasonic probe the sensitivity of which is controlled by a DC bias field is developed using an electrostrictive-ceramics-polymer composite as a transducer material. (1-x)Pb(Mg/sub 1/3/Nb/sub 2/3/)O/sub 3/-xPbTiO/sub 3/ electrostrictive-ceramics ((1-x)PMN-xPt) are used because they have a large electromechanical coupling factor for the thickness vibrational mode, k/sub t/, under a practical bias field. 0.91PMN-0.09PT/polyurethane 1-3 composites (thickness 0.22 mm, 7.5 MHz) are fabricated using a dicing and filling technique. The 0.91PMN-0.09PT has no residual k/sub t/ after removing the DC bias field around room temperature. Pulse-echo experimentation shows that the echo amplitude increases with the bias field, as expected from the relationship between k/sub t/ and the bias field.<<ETX>>","PeriodicalId":89469,"journal":{"name":"Proceedings. IEEE Ultrasonics Symposium","volume":"20 1","pages":"705-708 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1989.67077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

A medical ultrasonic probe the sensitivity of which is controlled by a DC bias field is developed using an electrostrictive-ceramics-polymer composite as a transducer material. (1-x)Pb(Mg/sub 1/3/Nb/sub 2/3/)O/sub 3/-xPbTiO/sub 3/ electrostrictive-ceramics ((1-x)PMN-xPt) are used because they have a large electromechanical coupling factor for the thickness vibrational mode, k/sub t/, under a practical bias field. 0.91PMN-0.09PT/polyurethane 1-3 composites (thickness 0.22 mm, 7.5 MHz) are fabricated using a dicing and filling technique. The 0.91PMN-0.09PT has no residual k/sub t/ after removing the DC bias field around room temperature. Pulse-echo experimentation shows that the echo amplitude increases with the bias field, as expected from the relationship between k/sub t/ and the bias field.<>
电致伸缩陶瓷/聚合物复合材料医用超声探头
采用电致伸缩-陶瓷-聚合物复合材料作为换能器材料,研制了一种由直流偏置场控制灵敏度的医用超声探头。使用(1-x)Pb(Mg/sub 1/3/Nb/sub 2/3/)O/sub 3/-xPbTiO/sub 3/电致伸缩陶瓷((1-x)PMN-xPt)是因为它们在实际偏置场下的厚度振动模式k/sub t/具有较大的机电耦合因子。0.91PMN-0.09PT/聚氨酯1-3复合材料(厚度0.22 mm, 7.5 MHz)采用切丁填充技术制备。0.91PMN-0.09PT在去除室温附近的直流偏置场后,没有k/sub /残余。脉冲回波实验表明,回波振幅随偏置场的增大而增大,与k/ t/与偏置场的关系一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书