The advantages of collimator optimization for intensity modulated radiation therapy

Brian E Doozan, Farrah Mohamed, E. Nourishirazi, S. Pella, T. Leventouri
{"title":"The advantages of collimator optimization for intensity modulated radiation therapy","authors":"Brian E Doozan, Farrah Mohamed, E. Nourishirazi, S. Pella, T. Leventouri","doi":"10.14319/ijcto.51.7","DOIUrl":null,"url":null,"abstract":"Purpose: The goal of this study was to improve dosimetry for pelvic, head and neck and other cancers with aspherical planning target volumes (PTV) using collimator optimization for intensity modulated radiation therapy (IMRT). Methods: A retroactive study on the effects of collimator optimization of 20 patients was done by comparing collimator angles from optimized plans in Eclipse version 11.0. Keeping all other parameters equal, plans were created with four collimator techniques: CA 0 , all fields have collimators set to 0°, CA­ E , using the Eclipse collimator optimization, CA A­, minimizing the area of the jaws around the PTV, and CA X , minimizing the x-jaw gap. The minimum area and the minimum x-jaw angles were found by evaluating each field beam’s eye view of the PTV with ImageJ and finding the desired parameters with a custom script. The evaluation of the plans included the monitor units (MU), the maximum dose of the plan, the maximum dose to organs at risk (OAR), the conformity index (CI) and the number of split fields. Results : Compared to the CA 0 plans, the monitor units decreased on average by 6% for the CA X with a p-value of 0.01 from an ANOVA test. The average maximum dose stayed within 1.1% between all four methods with the lowest being CA X . The maximum dose to the most at risk organ was best spared by the CA A , which decreased by 0.62% from the CA 0 . Minimizing the x-jaws significantly reduced the number of split field from 61 to 37. Conclusion: In every field tested the CA X optimization produced as good or superior results than the other three techniques. For aspherical PTVs, CA X on average reduced the number of split fields, the maximum dose, minimized the dose to the surrounding OAR, and reduced the MU all while achieving the same control of the PTV.","PeriodicalId":13931,"journal":{"name":"International Journal of Cancer Therapy and Oncology","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Cancer Therapy and Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14319/ijcto.51.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The goal of this study was to improve dosimetry for pelvic, head and neck and other cancers with aspherical planning target volumes (PTV) using collimator optimization for intensity modulated radiation therapy (IMRT). Methods: A retroactive study on the effects of collimator optimization of 20 patients was done by comparing collimator angles from optimized plans in Eclipse version 11.0. Keeping all other parameters equal, plans were created with four collimator techniques: CA 0 , all fields have collimators set to 0°, CA­ E , using the Eclipse collimator optimization, CA A­, minimizing the area of the jaws around the PTV, and CA X , minimizing the x-jaw gap. The minimum area and the minimum x-jaw angles were found by evaluating each field beam’s eye view of the PTV with ImageJ and finding the desired parameters with a custom script. The evaluation of the plans included the monitor units (MU), the maximum dose of the plan, the maximum dose to organs at risk (OAR), the conformity index (CI) and the number of split fields. Results : Compared to the CA 0 plans, the monitor units decreased on average by 6% for the CA X with a p-value of 0.01 from an ANOVA test. The average maximum dose stayed within 1.1% between all four methods with the lowest being CA X . The maximum dose to the most at risk organ was best spared by the CA A , which decreased by 0.62% from the CA 0 . Minimizing the x-jaws significantly reduced the number of split field from 61 to 37. Conclusion: In every field tested the CA X optimization produced as good or superior results than the other three techniques. For aspherical PTVs, CA X on average reduced the number of split fields, the maximum dose, minimized the dose to the surrounding OAR, and reduced the MU all while achieving the same control of the PTV.
准直器优化在调强放射治疗中的优势
目的:本研究的目的是利用准直优化技术改善骨盆、头颈部和其他具有非球面规划靶体积(PTV)的癌症的剂量学,用于调强放疗(IMRT)。方法:对20例患者的准直器优化效果进行回顾性研究,比较Eclipse 11.0版本优化方案的准直器角度。保持所有其他参数相同,使用四种准直器技术创建平面图:CA 0,所有字段的准直器设置为0°,CA - E,使用Eclipse准直器优化,CA A -,最小化PTV周围颚的面积,CA X,最小化X颚间隙。通过使用ImageJ评估PTV的每个场光束眼视图并使用自定义脚本找到所需的参数,找到最小面积和最小x颌角。对计划的评价包括监测单位(MU)、计划的最大剂量、危及器官的最大剂量(OAR)、符合指数(CI)和分裂场数。结果:与ca0计划相比,cax的监测单位平均减少了6%,方差分析的p值为0.01。4种方法的平均最大剂量均在1.1%以内,以CA X最低。最危险器官的最大剂量由CA A最大,比CA 0减少0.62%。最小化x颚显著减少了分割场的数量从61到37。结论:在各个领域的测试中,CA X优化产生的结果与其他三种技术一样好或更好。对于非球面PTV, CA X平均减少了分裂场的数量,最大剂量,最小化了对周围桨叶的剂量,并降低了MU,同时实现了对PTV的相同控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书