K. Saitoh, A. Fushimi, Y. Fujitani, K. Tanabe, Kei Sato, A. Takami, K. Sera
{"title":"Evaluation of elemental quantitative values of atmospheric aerosol samples by PIXE method","authors":"K. Saitoh, A. Fushimi, Y. Fujitani, K. Tanabe, Kei Sato, A. Takami, K. Sera","doi":"10.1142/S0129083515500023","DOIUrl":null,"url":null,"abstract":"In order to evaluate the quantitative values of atmospheric aerosol samples collected on filters, we investigated the effects of filter collection conditions (non-uniformity of collected particles) on analytical values and compared the quantitative values by means of PIXE and ICP-MS, using as the analytical sample PM2.5 collected on filters in a monitoring survey of atmospheric fine aerosol over the Kanto area of Japan in summer 2013. The results were as follows: (i) With respect to the uniformity of filter collection, differences in concentrations were seen for S and Cl as well as elements thought to originate in soil (Al, Si, Ti and Fe) depending on the analysis point, suggesting that collection of sulfate particles, chloride particles, and soil particles on filters was not uniform. (ii) According to a comparison of quantitative values yielded by PIXE and ICP-MS, ICP-MS values were lower than PIXE values for Mg, Al, Si, Ti and Fe, with Mg and Si being markedly lower. On the other hand, ICP-MS values were higher than PIXE values for Na, K, Ca and Zn. (iii) According to the results of measurement of NIST reference material and PM2.5 samples by means of PIXE and ICP-MS, Mg, Al, Si, Ca, Ti, Fe and Zn showed the same tendency. However, Na and K were opposite.","PeriodicalId":14345,"journal":{"name":"International Journal of PIXE","volume":"17 1","pages":"13-22"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of PIXE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S0129083515500023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In order to evaluate the quantitative values of atmospheric aerosol samples collected on filters, we investigated the effects of filter collection conditions (non-uniformity of collected particles) on analytical values and compared the quantitative values by means of PIXE and ICP-MS, using as the analytical sample PM2.5 collected on filters in a monitoring survey of atmospheric fine aerosol over the Kanto area of Japan in summer 2013. The results were as follows: (i) With respect to the uniformity of filter collection, differences in concentrations were seen for S and Cl as well as elements thought to originate in soil (Al, Si, Ti and Fe) depending on the analysis point, suggesting that collection of sulfate particles, chloride particles, and soil particles on filters was not uniform. (ii) According to a comparison of quantitative values yielded by PIXE and ICP-MS, ICP-MS values were lower than PIXE values for Mg, Al, Si, Ti and Fe, with Mg and Si being markedly lower. On the other hand, ICP-MS values were higher than PIXE values for Na, K, Ca and Zn. (iii) According to the results of measurement of NIST reference material and PM2.5 samples by means of PIXE and ICP-MS, Mg, Al, Si, Ca, Ti, Fe and Zn showed the same tendency. However, Na and K were opposite.