{"title":"Review of the Analytical Methods Based on HPLC-Electrochemical Detection Coupling for the Evaluation of Organic Compounds of Nutritional and Environmental Interest","authors":"Monica Maio, Cristina Di Fiore, Alessia Iannone, Fabiana Carriera, Ivan Notardonato, P. Avino","doi":"10.3390/analytica3010005","DOIUrl":null,"url":null,"abstract":"This review would like to show the state of the art regarding the coupling of High-Performance Liquid Chromatography (HPLC) with Electrochemical Detection (ED). Since a universal detector for HPLC is not available, the electrochemical detection methods, thanks to their versatility and specificity, are competitive with respect to the detectors currently used. The papers present in literature on HPLC-ED technique are analyzed and discussed: for example, they regard the development of analytical determinations of resveratrol, rosmarinic acid, aromatic heterocyclic amines and glyphosate in food matrices such as meat, aromatic plants, vegetables, fruit and tomato juices. These papers show that electrochemical sensors used as detectors for HPLC can offer better sensitivity values than other detectors. Furthermore, the use of specific working potentials allows avoid matrix interferences to be avoided by almost exclusively determining the analytes of interest. It should be underlined that HPLC-ED methods have a selectivity that allows for limitation of the sample preparation and clean-up procedures to a minimum, making them quick and easy to apply. In addition, these methods offer advantages such as the possibility of direct analysis, that derivatization is often not necessary, the cost-effectiveness of the instrumentation and the possibility of regenerating the electrodes which allows numerous analyses in succession.","PeriodicalId":7829,"journal":{"name":"Analytica","volume":"29 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/analytica3010005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This review would like to show the state of the art regarding the coupling of High-Performance Liquid Chromatography (HPLC) with Electrochemical Detection (ED). Since a universal detector for HPLC is not available, the electrochemical detection methods, thanks to their versatility and specificity, are competitive with respect to the detectors currently used. The papers present in literature on HPLC-ED technique are analyzed and discussed: for example, they regard the development of analytical determinations of resveratrol, rosmarinic acid, aromatic heterocyclic amines and glyphosate in food matrices such as meat, aromatic plants, vegetables, fruit and tomato juices. These papers show that electrochemical sensors used as detectors for HPLC can offer better sensitivity values than other detectors. Furthermore, the use of specific working potentials allows avoid matrix interferences to be avoided by almost exclusively determining the analytes of interest. It should be underlined that HPLC-ED methods have a selectivity that allows for limitation of the sample preparation and clean-up procedures to a minimum, making them quick and easy to apply. In addition, these methods offer advantages such as the possibility of direct analysis, that derivatization is often not necessary, the cost-effectiveness of the instrumentation and the possibility of regenerating the electrodes which allows numerous analyses in succession.
基于高效液相色谱-电化学耦合检测的营养与环境有机化合物评价方法综述
本文综述了高效液相色谱(HPLC)与电化学检测(ED)耦合的最新研究进展。由于没有一种通用的HPLC检测器,电化学检测方法由于其通用性和特异性,与目前使用的检测器相比具有竞争力。分析和讨论了HPLC-ED技术在肉类、芳香植物、蔬菜、水果和番茄汁等食品基质中白藜芦醇、迷迭香酸、芳香杂环胺和草甘膦的分析测定方面的进展。这些论文表明,电化学传感器作为HPLC检测器可以提供比其他检测器更好的灵敏度值。此外,使用特定的工作电位可以避免基体干扰,几乎可以完全确定感兴趣的分析物。应该强调的是,HPLC-ED方法具有选择性,允许将样品制备和清理程序限制到最低限度,使其快速且易于应用。此外,这些方法还具有直接分析的可能性(通常不需要衍生化)、仪器的成本效益以及再生电极的可能性(可以连续进行多次分析)等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信