{"title":"Monitoring of breathing tube position and patency in situ using reflected sound","authors":"J. P. Mansfield, G. R. Wodicka","doi":"10.1109/IEMBS.1995.575313","DOIUrl":null,"url":null,"abstract":"A new technique that acoustically interrogates an intubated breathing tube to yield clinically useful patency and position information was developed. A miniature speaker connected to the proximal tube end generates a sonic pulse that propagates down the tube, and the resulting echoes from within the tube and airways are measured by a miniature microphone. During intubations of anesthetized canines, the technique: 1) reliably differentiated between tracheal, bronchial, and esophageal intubations; 2) accurately quantified tube movements; 3) provided the location and degree of lumenal obstructions; and 4) detected extubation or disconnection from the ventilator hose. This technique offers an inexpensive and noninvasive mechanism to monitor breathing tubes in situ.","PeriodicalId":20509,"journal":{"name":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","volume":"134 1","pages":"687-688 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1995-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1995.575313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A new technique that acoustically interrogates an intubated breathing tube to yield clinically useful patency and position information was developed. A miniature speaker connected to the proximal tube end generates a sonic pulse that propagates down the tube, and the resulting echoes from within the tube and airways are measured by a miniature microphone. During intubations of anesthetized canines, the technique: 1) reliably differentiated between tracheal, bronchial, and esophageal intubations; 2) accurately quantified tube movements; 3) provided the location and degree of lumenal obstructions; and 4) detected extubation or disconnection from the ventilator hose. This technique offers an inexpensive and noninvasive mechanism to monitor breathing tubes in situ.