Proposal of framework for decision making of additional monitoring of eye lens dose for radiation workers

M. Kowatari, H. Yoshitomi, Tetsuya Ohishi, M. Yoshizawa
{"title":"Proposal of framework for decision making of additional monitoring of eye lens dose for radiation workers","authors":"M. Kowatari, H. Yoshitomi, Tetsuya Ohishi, M. Yoshizawa","doi":"10.15669/PNST.6.86","DOIUrl":null,"url":null,"abstract":"This work presents a framework of decision-making for additional monitoring of eye lens dose for radiation workers in reflect to the reduction of the annual dose limit of the eye lens dose. For a quantitative scheme to systematically estimate (non-) homogeneity of exposure, the proposed “homogeneity index (HI)” is introduced. The HIs were estimated by Monte Carlo calculations and found not to exceed up to 10 for γ-ray exposure situations. Applying the HI as a criterion of condition branching to decision-making process of additional monitoring of eye lens dose, proposed decision-making process was shown to cover entirely radiation workers required additional monitoring in the benchmark.","PeriodicalId":20706,"journal":{"name":"Progress in Nuclear Science and Technology","volume":"66 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15669/PNST.6.86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work presents a framework of decision-making for additional monitoring of eye lens dose for radiation workers in reflect to the reduction of the annual dose limit of the eye lens dose. For a quantitative scheme to systematically estimate (non-) homogeneity of exposure, the proposed “homogeneity index (HI)” is introduced. The HIs were estimated by Monte Carlo calculations and found not to exceed up to 10 for γ-ray exposure situations. Applying the HI as a criterion of condition branching to decision-making process of additional monitoring of eye lens dose, proposed decision-making process was shown to cover entirely radiation workers required additional monitoring in the benchmark.
对辐射工作人员进行额外眼镜片剂量监测的决策框架建议
这项工作提出了一个决策框架,用于对辐射工作人员进行额外的晶状体剂量监测,以反映晶状体剂量的年剂量限值的降低。为了系统地估计暴露(非)均匀性的定量方案,提出了“均匀性指数(HI)”。通过蒙特卡罗计算估计了HIs,发现γ射线暴露情况下HIs不超过10。将HI作为条件分支标准应用于晶体剂量附加监测的决策过程,表明所提出的决策过程完全覆盖了基准中需要附加监测的辐射工作人员。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信