E. V. Grabovskiĭ, S. L. Nedoseev, V. E. Pichugin, V. Smirnov, V.V. Zajivikhin, B.M. Oleynik
{"title":"Parallel MITLs current addition at common load","authors":"E. V. Grabovskiĭ, S. L. Nedoseev, V. E. Pichugin, V. Smirnov, V.V. Zajivikhin, B.M. Oleynik","doi":"10.1109/PPC.1995.599745","DOIUrl":null,"url":null,"abstract":"A parallel current addition at power facilities is carried out according to two main schemes as follows: (1) adding in generator water part installations \"SATURN\" and \"PBFA-II\" (SNL, USA); and (2) convolution in vacuum part \"Angara-5-1\" (TRINITI, Russia). The second scheme may be important for increasing of facilities' size, because it allows a decrease in vacuum isolator dimensions. The proposed paper deals with some experimental results on the parallel current addition at a common load. A jitter of parallel current addition is a significant effect of \"Angara-5-1\" operation. Quantitatively it is a square mean of time delay of modules T1-T8, when voltage of every module achieves 0.1 of its maximum value. These moments may be determined with +/-2 ns' accuracy.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":"10 1","pages":"1011-1016 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.599745","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A parallel current addition at power facilities is carried out according to two main schemes as follows: (1) adding in generator water part installations "SATURN" and "PBFA-II" (SNL, USA); and (2) convolution in vacuum part "Angara-5-1" (TRINITI, Russia). The second scheme may be important for increasing of facilities' size, because it allows a decrease in vacuum isolator dimensions. The proposed paper deals with some experimental results on the parallel current addition at a common load. A jitter of parallel current addition is a significant effect of "Angara-5-1" operation. Quantitatively it is a square mean of time delay of modules T1-T8, when voltage of every module achieves 0.1 of its maximum value. These moments may be determined with +/-2 ns' accuracy.