{"title":"A successful repair of a ruptured giant abdominal aortic aneurysm","authors":"Dragan Piljic, M. Tabaković, A. C., Dilista Piljić, N. Sehic, Tarik Bakalovic, A. Skakić, Mirza Tokic, Fahrudin Sabanovic, M. Petricevic","doi":"10.15761/hpc.1000172","DOIUrl":null,"url":null,"abstract":"A 78-year old man with a medical history of smoking, hyperlipidemia and hypertension was admitted to our department with ruptured abdominal aortic aneurysm (AAA) diagnosed by ultrasonography of the abdomen. The blood pressure was 60/20 mm Hg. An emergent computed tomography scan of the abdomen revealed a rupture of a giant infrarenal AAA of 16 cm in diameter with extensive intraluminal thrombus, evidence of rupture and large intraabdominal hematoma. The patient underwent a successful open surgical repair with placement of a Dacron tube graft 18 mm. The patient was transferred to the intensive care unit following successful surgical repair. Patient was transferred to the Department of cardiovascular surgery on postoperative day 2. Postoperative recovery resulted in hospital discharge at postoperative day 12.","PeriodicalId":48703,"journal":{"name":"Primary Health Care Research and Development","volume":"120 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Primary Health Care Research and Development","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.15761/hpc.1000172","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PRIMARY HEALTH CARE","Score":null,"Total":0}
引用次数: 0
Abstract
A 78-year old man with a medical history of smoking, hyperlipidemia and hypertension was admitted to our department with ruptured abdominal aortic aneurysm (AAA) diagnosed by ultrasonography of the abdomen. The blood pressure was 60/20 mm Hg. An emergent computed tomography scan of the abdomen revealed a rupture of a giant infrarenal AAA of 16 cm in diameter with extensive intraluminal thrombus, evidence of rupture and large intraabdominal hematoma. The patient underwent a successful open surgical repair with placement of a Dacron tube graft 18 mm. The patient was transferred to the intensive care unit following successful surgical repair. Patient was transferred to the Department of cardiovascular surgery on postoperative day 2. Postoperative recovery resulted in hospital discharge at postoperative day 12.
期刊介绍:
Primary Health Care Research & Development is aimed specifically at both researchers and practitioners in primary health care, bridging the gap between the two areas. It provides a forum for the publication of international, interdisciplinary research and development in primary health care. It is essential reading for all involved in primary care: nurse practitioners, GPs and health service managers; professional and local groups in community health; researchers and academics; purchasers of primary health care services; allied health practitioners in secondary services and health-related consumer groups.