A predictive current control of voltage source inverters for common-mode current attenuation

Jiefeng Hu, Qishuang Ma, Chuanqi Ren, D. Dorrell
{"title":"A predictive current control of voltage source inverters for common-mode current attenuation","authors":"Jiefeng Hu, Qishuang Ma, Chuanqi Ren, D. Dorrell","doi":"10.1109/ECCE.2015.7310267","DOIUrl":null,"url":null,"abstract":"The development of distributed generation (DG) systems has led to the increasing use of voltage source inverters. However, step-changes in the modulated voltage can produce dangerous peak common-mode currents (CMCs), which can interfere with the power system ground and cause detrimental effects on other equipment. In this paper, the root cause of CMCs is explored and analyzed. After this, a new method which combines of a modified inverter topology and a predictive current control scheme is developed. The test results show that the proposed method effectively controls the load current while the CMCs can be reduced significantly.","PeriodicalId":6654,"journal":{"name":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"8 1","pages":"4295-4300"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2015.7310267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The development of distributed generation (DG) systems has led to the increasing use of voltage source inverters. However, step-changes in the modulated voltage can produce dangerous peak common-mode currents (CMCs), which can interfere with the power system ground and cause detrimental effects on other equipment. In this paper, the root cause of CMCs is explored and analyzed. After this, a new method which combines of a modified inverter topology and a predictive current control scheme is developed. The test results show that the proposed method effectively controls the load current while the CMCs can be reduced significantly.
用于共模电流衰减的电压源逆变器的预测电流控制
分布式发电(DG)系统的发展导致越来越多地使用电压源逆变器。然而,调制电压的阶跃变化会产生危险的峰值共模电流(cmc),它会干扰电力系统接地并对其他设备造成不利影响。本文对cmc产生的根本原因进行了探讨和分析。在此基础上,提出了一种将改进的逆变器拓扑与预测电流控制相结合的方法。试验结果表明,该方法有效地控制了负载电流,显著减小了cmc的损耗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信