Numerical analysis of seismic behavior of square concrete filled steel tubular columns

H D Phan
{"title":"Numerical analysis of seismic behavior of square concrete filled steel tubular columns","authors":"H D Phan","doi":"10.31814/STCE.NUCE2021-15(2)-11","DOIUrl":null,"url":null,"abstract":"This paper presents a numerical analysis of the seismic behavior of square concrete filled steel tubular (CFST) columns. Finite element analysis (FEA) models in ABAQUS software were used to simulate a series of columns subjected to axial compression and cyclic lateral loading. The CFST columns were simulated using nonlinear tri-dimensional (3-D) finite elements for the infilled concrete, and nonlinear two-dimensional (2-D) finite elements for the steel tube. The feasibility of the FEA model has been validated by published experimental results. The validated FEA model was further extended to conduct parametric studies with various parameters including axial load level (n), width-to-thickness ratio of steel tube (B/t), and concrete strength. The numerical analysis results reveal that with the same B/t and constitute materials, the higher the axial compression, the lower the shear strength and deformation capacity were. The thicker steel wall (B/t = 21) resulted in higher strength and larger deformation capacity of the column. Increasing concrete strength helped to significantly develop the column’s shear strength in all cases. Meanwhile, it just led to an increase in deformation capacity in some cases depending on n and B/t. This study also reveals that the square CFST columns with B/t of 21 satisfy the seismic performance demand in high seismic zones (ultimate interstory drift ratio (IDRu) not less than 3% radian) under the two axial load levels, 0.35 and 0.45, but the columns with B/t of 28 satisfy the above demand under just one axial load level of 0.35. \nKeywords: \nsquare concrete filled steel tubular (CFST) columns; finite element analysis (FEA) model; width-to-thickness ratio (B/t); high axial load level; seismic behavior.","PeriodicalId":17004,"journal":{"name":"Journal of Science and Technology in Civil Engineering (STCE) - NUCE","volume":"45 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Science and Technology in Civil Engineering (STCE) - NUCE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31814/STCE.NUCE2021-15(2)-11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper presents a numerical analysis of the seismic behavior of square concrete filled steel tubular (CFST) columns. Finite element analysis (FEA) models in ABAQUS software were used to simulate a series of columns subjected to axial compression and cyclic lateral loading. The CFST columns were simulated using nonlinear tri-dimensional (3-D) finite elements for the infilled concrete, and nonlinear two-dimensional (2-D) finite elements for the steel tube. The feasibility of the FEA model has been validated by published experimental results. The validated FEA model was further extended to conduct parametric studies with various parameters including axial load level (n), width-to-thickness ratio of steel tube (B/t), and concrete strength. The numerical analysis results reveal that with the same B/t and constitute materials, the higher the axial compression, the lower the shear strength and deformation capacity were. The thicker steel wall (B/t = 21) resulted in higher strength and larger deformation capacity of the column. Increasing concrete strength helped to significantly develop the column’s shear strength in all cases. Meanwhile, it just led to an increase in deformation capacity in some cases depending on n and B/t. This study also reveals that the square CFST columns with B/t of 21 satisfy the seismic performance demand in high seismic zones (ultimate interstory drift ratio (IDRu) not less than 3% radian) under the two axial load levels, 0.35 and 0.45, but the columns with B/t of 28 satisfy the above demand under just one axial load level of 0.35. Keywords: square concrete filled steel tubular (CFST) columns; finite element analysis (FEA) model; width-to-thickness ratio (B/t); high axial load level; seismic behavior.
方钢管混凝土柱抗震性能数值分析
本文对方钢管混凝土柱的抗震性能进行了数值分析。采用ABAQUS软件中的有限元分析(FEA)模型对一系列柱进行了轴压和循环侧向加载的模拟。对钢管混凝土柱进行了非线性三维有限元模拟,对钢管柱进行了非线性二维有限元模拟。已发表的实验结果验证了有限元模型的可行性。对验证后的有限元模型进行进一步扩展,采用轴向荷载水平(n)、钢管宽厚比(B/t)、混凝土强度等参数进行参数化研究。数值分析结果表明,在相同的B/t和构成材料条件下,轴压越高,抗剪强度和变形能力越低。钢壁越厚(B/t = 21),柱的强度越高,变形能力越大。提高混凝土强度有助于显著提高柱的抗剪强度在所有情况下。同时,它只是在某些情况下导致变形能力的增加,这取决于n和B/t。研究还表明,在0.35和0.45两种轴向荷载水平下,B/t为21的方钢管混凝土柱满足高震区(极限层间位移比(IDRu)不小于3%)的抗震性能要求,而B/t为28的方钢管混凝土柱在0.35一种轴向荷载水平下满足上述要求。关键词:方钢管混凝土柱;有限元分析模型;宽厚比(B/t);高轴向载荷水平;地震的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信