Human Subjects Protection by Monitoring the Stabilized Supply Voltages of the Medical Equipment

L. Pîslaru-Dănescu, G. Zărnescu, V. Stoica
{"title":"Human Subjects Protection by Monitoring the Stabilized Supply Voltages of the Medical Equipment","authors":"L. Pîslaru-Dănescu, G. Zărnescu, V. Stoica","doi":"10.46904/eea.22.70.3.1108001","DOIUrl":null,"url":null,"abstract":"This study addresses a sensitive topic, namely how human subjects undergoing medical procedures can be protected by means of medical electrical equipment. A solution to this problem is to monitor the stabilized electrical supply voltages of the medical equipment. The net effect of the proposed protection is the automatic disconnection of the medical equipment from the alternating voltage network supplying the medical equipment. This disconnection must be done without using electrical switching devices that contain electrical contacts that can generate electrical sparks. This is because most of the time the medical equipment is placed in an area where pure oxygen or other combustible gases predominate. Therefore, only static relays are used in this case. The realized electronic module has been tested in the laboratory and is capable of automatic disconnection of any medical equipment from the 230 V~, f = 50 Hz AC power supply in the case of major faults, which can be caused by accidental overvoltage on the electric energy supply lines, accidental overtemperatures, transient overvoltage which are propagated during storms, etc. This study presents the transient phenomena that occur in the immediate vicinity of the monitored voltages range. Finally, a solution for simultaneous monitoring of four electric voltages and/or currents is presented.","PeriodicalId":38292,"journal":{"name":"EEA - Electrotehnica, Electronica, Automatica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EEA - Electrotehnica, Electronica, Automatica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46904/eea.22.70.3.1108001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study addresses a sensitive topic, namely how human subjects undergoing medical procedures can be protected by means of medical electrical equipment. A solution to this problem is to monitor the stabilized electrical supply voltages of the medical equipment. The net effect of the proposed protection is the automatic disconnection of the medical equipment from the alternating voltage network supplying the medical equipment. This disconnection must be done without using electrical switching devices that contain electrical contacts that can generate electrical sparks. This is because most of the time the medical equipment is placed in an area where pure oxygen or other combustible gases predominate. Therefore, only static relays are used in this case. The realized electronic module has been tested in the laboratory and is capable of automatic disconnection of any medical equipment from the 230 V~, f = 50 Hz AC power supply in the case of major faults, which can be caused by accidental overvoltage on the electric energy supply lines, accidental overtemperatures, transient overvoltage which are propagated during storms, etc. This study presents the transient phenomena that occur in the immediate vicinity of the monitored voltages range. Finally, a solution for simultaneous monitoring of four electric voltages and/or currents is presented.
监测医疗设备稳定电源电压对人体的保护
本研究涉及一个敏感话题,即如何通过医疗电气设备保护接受医疗程序的人类受试者。解决这个问题的一种方法是监测医疗设备的稳定电源电压。所建议的保护的净效果是自动断开医疗设备与供应医疗设备的交流电压网络的连接。这种断开必须在不使用包含可能产生电火花的电触点的电气开关设备的情况下进行。这是因为大多数时候,医疗设备被放置在纯氧或其他可燃气体占主导地位的区域。因此,在这种情况下只使用静态继电器。所实现的电子模块已经过实验室测试,能够在供电线路意外过电压、意外过温、风暴传播的瞬态过电压等重大故障时,自动断开任何医疗设备与230 V~, f = 50 Hz交流电源的连接。本研究提出了发生在被监测电压范围附近的暂态现象。最后,提出了一种同时监测四个电压和/或电流的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
EEA - Electrotehnica, Electronica, Automatica
EEA - Electrotehnica, Electronica, Automatica Engineering-Electrical and Electronic Engineering
CiteScore
0.90
自引率
0.00%
发文量
26
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信