Effects of different bleaching agent concentrations on surface roughness and microhardness of esthetic restorative materials

Salma A. Bahannan
{"title":"Effects of different bleaching agent concentrations on surface roughness and microhardness of esthetic restorative materials","authors":"Salma A. Bahannan","doi":"10.1016/j.sjdr.2015.01.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>The study assessed the changes in surface roughness and microhardness of three esthetic restorative materials after bleaching with 10%, 20% and 35% carbamide peroxide (CP).</p></div><div><h3>Methods</h3><p>Standardized cylindrical specimens (<em>n</em> <!-->=<!--> <!-->210) of 3 esthetic materials (nano composite resin (NC), resin modified glass ionomer (GI), feldspathic porcelain (FP) were fabricated (<em>n</em> <!-->=<!--> <!-->70). They were divided into 3 groups (<em>n</em> <!-->=<!--> <!-->20) and a control group (<em>n</em> <!-->=<!--> <!-->10). Each group was bleached with different concentrations of CP. The specimens of group 1 and 2 (10% CP and 20% CP) were immersed in the bleaching gels for 6<!--> <!-->h daily, while group 3 (35% CP) was immersed for 30<!--> <!-->min weekly. The control group was stored in artificial saliva. After 21<!--> <!-->days, the morphological changes of the specimens were investigated with surface texture analyzer, while the hardness was assessed by performing superficial microhardness analysis. The data were analyzed with one-way ANOVA, and Scheffe test at <em>α</em> <!-->=<!--> <!-->0.05.</p></div><div><h3>Results</h3><p>No significant differences in roughness average (Ra) were recorded among the control group and 10% CP bleached groups of all tested restorative materials (NC (<em>p</em> <!-->=<!--> <!-->0.1495), GI (<em>p</em> <!-->=<!--> <!-->0.0761), FP (<em>p</em> <!-->=<!--> <!-->0.2848)). However, there were significant differences in Ra among the control group, 20% CP, and 35% CP (<em>p</em> <!-->&lt;<!--> <!-->0.05). There were no significant differences in the microhardness of feldspathic porcelain (10% (<em>p</em> <!-->=<!--> <!-->0.0786), 20% (<em>p</em> <!-->=<!--> <!-->0.1041), and 35% (<em>p</em> <!-->=<!--> <!-->0.2066). While nano composite resin and resin modified glass ionomer specimens were significantly affected by concentration of 20% and 35% CP (<em>p</em> <!-->&lt;<!--> <!-->0.05).</p></div><div><h3>Conclusion</h3><p>The effect of bleaching depends on the concentration of CP. The higher surface roughness was produced by 35% CP. Bleaching with different concentrations did not reduce the microhardness of the feldspathic porcelain. However, microhardness of nano composite resin and resin modified glass ionomer specimens was affected by 20% CP and 35% CP.</p></div>","PeriodicalId":101249,"journal":{"name":"The Saudi Journal for Dental Research","volume":"6 2","pages":"Pages 124-128"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.sjdr.2015.01.002","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Saudi Journal for Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352003515000039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

Objectives

The study assessed the changes in surface roughness and microhardness of three esthetic restorative materials after bleaching with 10%, 20% and 35% carbamide peroxide (CP).

Methods

Standardized cylindrical specimens (n = 210) of 3 esthetic materials (nano composite resin (NC), resin modified glass ionomer (GI), feldspathic porcelain (FP) were fabricated (n = 70). They were divided into 3 groups (n = 20) and a control group (n = 10). Each group was bleached with different concentrations of CP. The specimens of group 1 and 2 (10% CP and 20% CP) were immersed in the bleaching gels for 6 h daily, while group 3 (35% CP) was immersed for 30 min weekly. The control group was stored in artificial saliva. After 21 days, the morphological changes of the specimens were investigated with surface texture analyzer, while the hardness was assessed by performing superficial microhardness analysis. The data were analyzed with one-way ANOVA, and Scheffe test at α = 0.05.

Results

No significant differences in roughness average (Ra) were recorded among the control group and 10% CP bleached groups of all tested restorative materials (NC (p = 0.1495), GI (p = 0.0761), FP (p = 0.2848)). However, there were significant differences in Ra among the control group, 20% CP, and 35% CP (p < 0.05). There were no significant differences in the microhardness of feldspathic porcelain (10% (p = 0.0786), 20% (p = 0.1041), and 35% (p = 0.2066). While nano composite resin and resin modified glass ionomer specimens were significantly affected by concentration of 20% and 35% CP (p < 0.05).

Conclusion

The effect of bleaching depends on the concentration of CP. The higher surface roughness was produced by 35% CP. Bleaching with different concentrations did not reduce the microhardness of the feldspathic porcelain. However, microhardness of nano composite resin and resin modified glass ionomer specimens was affected by 20% CP and 35% CP.

不同漂白剂浓度对美观修复材料表面粗糙度和显微硬度的影响
目的观察10%、20%和35%过氧化脲(CP)漂白后三种美容修复材料的表面粗糙度和显微硬度的变化。方法制备纳米复合树脂(NC)、树脂改性玻璃离聚体(GI)、长石瓷(FP) 3种美学材料的标准化圆柱形试样(n = 210) (n = 70)。将患者分为3组(n = 20)和对照组(n = 10)。各组分别用不同浓度的CP进行漂白,1组和2组(10% CP和20% CP)每天浸泡6 h, 3组(35% CP)每周浸泡30 min。对照组保存在人工唾液中。21 d后,用表面织构仪观察样品的形态变化,通过表面显微硬度分析评估硬度。资料分析采用单因素方差分析,采用Scheffe检验,α = 0.05。结果所有修复材料(NC (p = 0.1495)、GI (p = 0.0761)、FP (p = 0.2848)的粗糙度平均值(Ra)在对照组和10% CP漂白组之间均无显著差异。然而,Ra在对照组、20% CP组和35% CP组之间存在显著差异(p <0.05)。长石瓷的显微硬度分别为10% (p = 0.0786)、20% (p = 0.1041)和35% (p = 0.2066),差异无统计学意义。20%和35% CP浓度对纳米复合树脂和树脂改性玻璃离聚体样品的影响显著(p <0.05)。结论漂白效果与CP的浓度有关,35% CP漂白后的长石瓷表面粗糙度较高,不同浓度的漂白均未降低长石瓷的显微硬度。20% CP和35% CP对纳米复合树脂和树脂改性玻璃离聚体试样的显微硬度有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信