Simultaneous Estimation and Validation of Niacin and Atorvastatin Calcium by UV-Spectroscopy in Pure and Tablet Dosage Form Using Methanol: Water Mixture as Solvent

M. Ranganath, R. Chowdary
{"title":"Simultaneous Estimation and Validation of Niacin and Atorvastatin Calcium by UV-Spectroscopy in Pure and Tablet Dosage Form Using Methanol: Water Mixture as Solvent","authors":"M. Ranganath, R. Chowdary","doi":"10.5530/RJPS.2014.2.6","DOIUrl":null,"url":null,"abstract":"Purpose of This paper: Two simple, precise, rapid, sensitive and accurate simultaneous estimation by UV spectrophotometric methods were developed and validated for niacin (NCN) and atorvastatin calcium (ATR) in pure and tablet dosage form using methanol: water (40:60 v/v)mixture as solvent. Design and methodology: Two methods were developed, Method 1: was based on the simultaneous equation (Veroirdt's) method where as Method 2:was based on Q-analysis method. Findings: The absorption maxima were found to be 262 nm and 246 nm for niacin and atorvastatin calcium respectively. Both the drugs showed isosbestic point at 250 nm. Beer’s range was in the concentration range of 10-50 μg/ml for niacin and 4-20 μg/ml for atorvastatin calcium with correlation coefficient within the range of 0.9974 – 0.9998 for both the drugs. Recovery studies were performed to assess the accuracy of the methods, the results were found to be between 99.39 ± 0.7614 and 100.63 ± 0.3876 for niacin; 97. 71 ± 0.3131 and 99.06 ± 0.5625 for atorvastatin calcium. Research implications/limitations: The above two methods has been validated according to ICH guidelines. Practical implications: Hence the above methods can be used for routine analysis of NCN and ATR in pharmaceutical industries and research institutions.","PeriodicalId":21459,"journal":{"name":"RGUHS Journal of Pharmaceutical Sciences","volume":"2 1","pages":"70-77"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RGUHS Journal of Pharmaceutical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5530/RJPS.2014.2.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Purpose of This paper: Two simple, precise, rapid, sensitive and accurate simultaneous estimation by UV spectrophotometric methods were developed and validated for niacin (NCN) and atorvastatin calcium (ATR) in pure and tablet dosage form using methanol: water (40:60 v/v)mixture as solvent. Design and methodology: Two methods were developed, Method 1: was based on the simultaneous equation (Veroirdt's) method where as Method 2:was based on Q-analysis method. Findings: The absorption maxima were found to be 262 nm and 246 nm for niacin and atorvastatin calcium respectively. Both the drugs showed isosbestic point at 250 nm. Beer’s range was in the concentration range of 10-50 μg/ml for niacin and 4-20 μg/ml for atorvastatin calcium with correlation coefficient within the range of 0.9974 – 0.9998 for both the drugs. Recovery studies were performed to assess the accuracy of the methods, the results were found to be between 99.39 ± 0.7614 and 100.63 ± 0.3876 for niacin; 97. 71 ± 0.3131 and 99.06 ± 0.5625 for atorvastatin calcium. Research implications/limitations: The above two methods has been validated according to ICH guidelines. Practical implications: Hence the above methods can be used for routine analysis of NCN and ATR in pharmaceutical industries and research institutions.
以甲醇:水为溶剂,紫外光谱法同时测定烟酸和阿托伐他汀钙在纯剂型和片剂中的含量
目的:以甲醇:水(40:60 v/v)为溶剂,建立了两种简便、精确、快速、灵敏、准确的紫外分光光度法同时测定烟酸(NCN)和阿托伐他汀钙(ATR)纯剂型和片剂剂型的方法,并进行了验证。设计与方法学:设计了两种方法,方法1采用Veroirdt联立方程法,方法2采用q分析法。结果:烟酸和阿托伐他汀钙的吸光度最大值分别为262 nm和246 nm。两种药物均在250 nm处出现等吸点。烟酸浓度范围在10 ~ 50 μg/ml,阿托伐他汀钙浓度范围在4 ~ 20 μg/ml,相关系数在0.9974 ~ 0.9998范围内。结果表明,烟酸的回收率在99.39±0.7614 ~ 100.63±0.3876之间;97. 阿托伐他汀钙为71±0.3131和99.06±0.5625。研究意义/局限性:上述两种方法已根据ICH指南进行了验证。实际意义:因此,上述方法可用于制药工业和研究机构的NCN和ATR的常规分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信