A Guitaring Technique with 035 Wire and Perforated Coronary Balloon for Thrombolysis in the Treatment of Acute Deep Vein Thrombosis

IF 0.6 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
M. Arokiaraj
{"title":"A Guitaring Technique with 035 Wire and Perforated Coronary Balloon for Thrombolysis in the Treatment of Acute Deep Vein Thrombosis","authors":"M. Arokiaraj","doi":"10.2478/jce-2019-0012","DOIUrl":null,"url":null,"abstract":"Abstract A patient who underwent thrombolysis and inferior vena cava filter implantation for acute deep vein thrombosis treatment nine years before, presented with deep vein thrombosis on the other limb. The venous angiogram showed deep vein thrombosis in the ilio-femoral vessels. Through left femoral vein puncture, a 6F right Judkins diagnostic catheter was advanced up to the proximal iliac veins, and further advancement was not possible. Hence, a 035 hydrophilic wire was advanced, and through a guitaring technique, the clots were disrupted at the mid-thigh level. Through a 014 coronary wire, a punctured coronary balloon was placed at the distal mid-thigh level, and intravascular thrombolysis was performed for 12 hours, followed by removal of the balloon and the right coronary Judkins catheters. The leg swelling reduced in the first day, and subsequently, the patient was followed up for 7 months with anticoagulation and good resolution of the symptoms.","PeriodicalId":15210,"journal":{"name":"Journal Of Cardiovascular Emergencies","volume":"23 1","pages":"104 - 107"},"PeriodicalIF":0.6000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal Of Cardiovascular Emergencies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jce-2019-0012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract A patient who underwent thrombolysis and inferior vena cava filter implantation for acute deep vein thrombosis treatment nine years before, presented with deep vein thrombosis on the other limb. The venous angiogram showed deep vein thrombosis in the ilio-femoral vessels. Through left femoral vein puncture, a 6F right Judkins diagnostic catheter was advanced up to the proximal iliac veins, and further advancement was not possible. Hence, a 035 hydrophilic wire was advanced, and through a guitaring technique, the clots were disrupted at the mid-thigh level. Through a 014 coronary wire, a punctured coronary balloon was placed at the distal mid-thigh level, and intravascular thrombolysis was performed for 12 hours, followed by removal of the balloon and the right coronary Judkins catheters. The leg swelling reduced in the first day, and subsequently, the patient was followed up for 7 months with anticoagulation and good resolution of the symptoms.
035金属丝加冠脉球囊穿刺溶栓治疗急性深静脉血栓
摘要1例患者于9年前行溶栓及下腔静脉滤器植入术治疗急性深静脉血栓形成,另一侧肢体出现深静脉血栓形成。静脉造影显示髂股血管深静脉血栓形成。通过左股静脉穿刺,一根6F右Judkins诊断导管向前推进至髂近端静脉,不能再向前推进。因此,我们采用了一种035型亲水金属丝,并通过一种吉他技术,在大腿中部破坏了血块。通过014冠状动脉导线,穿刺冠状动脉球囊置于股骨远端中水平,血管内溶栓12小时,随后取出球囊和右侧冠状动脉Judkins导管。第一天腿部肿胀减轻,随后随访7个月,抗凝治疗,症状好转。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
4
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信