{"title":"The role of microconstituents on the fatigue failure of bone cement","authors":"Martin Browne ,&nbsp;Natalie Shearwood-Porter ,&nbsp;Ian Sinclair","doi":"10.1016/j.proeng.2018.02.011","DOIUrl":null,"url":null,"abstract":"<div><p>Implant fixation via the use of acrylic bone cement is now a well-established practice in orthopaedics. Excellent long-term clinical results are evidenced in national joint registers based on over 5 decades of clinical experience. Increased life expectancies, patient BMI, together with the need to remain active in later life, are expected to put greater demands on the materials used in load bearing joint arthroplasty. Failure of bone cement and its interfaces with the implant and bone often leads to loosening, requiring revision surgery. This is a particularly invasive procedure, with lower long-term success rates compared to the primary procedure. To reduce the incidence of bone cement failure, it is necessary to understand the origins of failure <em>in vivo</em>. In the past, bulk failure of bone cement has been attributed to damage accumulation originating at pores. Advances in imaging technology now mean that we are able to observe cement microconstituents readily and identify crack-initiating defects more precisely as we attempt to understand origins of failure. The role of radiopacifier particles within the bone cement has not been examined extensively to date, and the present study demonstrates that this microconstituent could be in crack formation due in part to its ability to agglomerate and not bond with the surrounding matrix. To verify this hypothesis, explanted bone cement and laboratory tested bone cement are compared and correlations in failure mechanisms are discussed.</p></div>","PeriodicalId":20470,"journal":{"name":"Procedia Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.proeng.2018.02.011","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Procedia Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1877705818302339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Implant fixation via the use of acrylic bone cement is now a well-established practice in orthopaedics. Excellent long-term clinical results are evidenced in national joint registers based on over 5 decades of clinical experience. Increased life expectancies, patient BMI, together with the need to remain active in later life, are expected to put greater demands on the materials used in load bearing joint arthroplasty. Failure of bone cement and its interfaces with the implant and bone often leads to loosening, requiring revision surgery. This is a particularly invasive procedure, with lower long-term success rates compared to the primary procedure. To reduce the incidence of bone cement failure, it is necessary to understand the origins of failure in vivo. In the past, bulk failure of bone cement has been attributed to damage accumulation originating at pores. Advances in imaging technology now mean that we are able to observe cement microconstituents readily and identify crack-initiating defects more precisely as we attempt to understand origins of failure. The role of radiopacifier particles within the bone cement has not been examined extensively to date, and the present study demonstrates that this microconstituent could be in crack formation due in part to its ability to agglomerate and not bond with the surrounding matrix. To verify this hypothesis, explanted bone cement and laboratory tested bone cement are compared and correlations in failure mechanisms are discussed.

微组分在骨水泥疲劳破坏中的作用
使用丙烯酸骨水泥植入物固定是目前骨科的一种成熟做法。基于50多年临床经验的国家联合登记证明了良好的长期临床结果。预期寿命的增加,患者的身体质量指数,以及在以后的生活中保持活跃的需要,预计会对承重关节置换术中使用的材料提出更高的要求。骨水泥及其与种植体和骨的界面失效通常会导致松动,需要翻修手术。这是一种特别具有侵入性的手术,与初级手术相比,长期成功率较低。为了减少骨水泥失效的发生率,有必要了解体内失效的起源。过去,骨水泥的整体破坏被认为是由孔隙损伤积累引起的。成像技术的进步现在意味着我们能够很容易地观察水泥微成分,并在我们试图了解失败的起源时更精确地识别裂缝引发缺陷。迄今为止,还没有对骨水泥中放射性不透明颗粒的作用进行过广泛的研究,目前的研究表明,这种微成分可能会形成裂缝,部分原因是它具有凝聚而不与周围基质结合的能力。为了验证这一假设,对外植骨水泥和实验室测试骨水泥进行了比较,并讨论了破坏机制中的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信