Research on high voltage capacitor partial discharge detection with portable oscillating wave circuit

Lingying Chen, Guangke Xu, Panfeng Shang
{"title":"Research on high voltage capacitor partial discharge detection with portable oscillating wave circuit","authors":"Lingying Chen, Guangke Xu, Panfeng Shang","doi":"10.1109/ICEMPE51623.2021.9509209","DOIUrl":null,"url":null,"abstract":"At present, the partial discharge(PD) detection of high voltage power capacitor usually employs a resonant circuit which requires a very bulky reactor, and a PD detector with ultrasonic sensors. One of the problems with this approach is difficult experimental setup. Another is the limitation of PD signal analyze and get further valuable information, due to the properties of ultrasonic signal itself. This paper reports on a new user-friendly and effective way to carry out PD test of HV power capacitor. This system contains a supply module, a specially made sampling impedance and a PD pulse collector. The supply module, consists of high voltage DC power generator, protection resistance, damping resistance, semiconductor switch, which is integrated designed, characterized by small size, light weight, and low power consumption. The specially made sampling impedance which is employed to obtain PD signals could be applied to the detection of capacitor samples with different capacity, and the impedance can be directly connected to the end of the capacitor without the influence of large current signal. And the PD pulse collector is different from PD detectors under stable voltage, which needs to grasp the PD signal accurately in several cycles of the test loop oscillation, and the signal acquisition is required to be continuous. Compared with the previous approach, the oscillating wave circuit with specially made impedance reported in this paper, showed much more portability for large power capacitors PD detection, and the results provided chances for time and frequency domain spectrum analysis, which could be helpful to identify the PD type of HV power capacitors.","PeriodicalId":7083,"journal":{"name":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","volume":"5 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMPE51623.2021.9509209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

At present, the partial discharge(PD) detection of high voltage power capacitor usually employs a resonant circuit which requires a very bulky reactor, and a PD detector with ultrasonic sensors. One of the problems with this approach is difficult experimental setup. Another is the limitation of PD signal analyze and get further valuable information, due to the properties of ultrasonic signal itself. This paper reports on a new user-friendly and effective way to carry out PD test of HV power capacitor. This system contains a supply module, a specially made sampling impedance and a PD pulse collector. The supply module, consists of high voltage DC power generator, protection resistance, damping resistance, semiconductor switch, which is integrated designed, characterized by small size, light weight, and low power consumption. The specially made sampling impedance which is employed to obtain PD signals could be applied to the detection of capacitor samples with different capacity, and the impedance can be directly connected to the end of the capacitor without the influence of large current signal. And the PD pulse collector is different from PD detectors under stable voltage, which needs to grasp the PD signal accurately in several cycles of the test loop oscillation, and the signal acquisition is required to be continuous. Compared with the previous approach, the oscillating wave circuit with specially made impedance reported in this paper, showed much more portability for large power capacitors PD detection, and the results provided chances for time and frequency domain spectrum analysis, which could be helpful to identify the PD type of HV power capacitors.
便携式振荡波电路高压电容器局部放电检测的研究
目前,高压电力电容器局部放电检测通常采用谐振电路,需要非常笨重的电抗器和带有超声波传感器的局部放电检测器。这种方法的一个问题是实验设置困难。另一个是由于超声信号本身的特性,限制了PD信号的分析和进一步获得有价值的信息。本文介绍了一种简便有效的高压电容器局部放电试验方法。该系统包含一个电源模块、一个特制的采样阻抗和一个PD脉冲收集器。电源模块由高压直流发电机、保护电阻、阻尼电阻、半导体开关组成,采用一体化设计,具有体积小、重量轻、功耗低等特点。采用特制的采样阻抗获取PD信号,可用于检测不同容量的电容样品,且该阻抗可直接连接到电容的端部,不受大电流信号的影响。而PD脉冲集电极不同于稳定电压下的PD检测器,需要在测试回路振荡的几个周期内准确地抓取PD信号,并且要求信号采集是连续的。与以往的方法相比,本文所报道的具有特殊阻抗的振荡波电路对大型电力电容器局部放电检测具有更强的可移植性,并且为进行时频域频谱分析提供了机会,有助于高压电力电容器局部放电类型的识别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信