{"title":"Leakage Currents on the Distribution Post Insulator with Different Profile Factors","authors":"Moch. Dhofir, Unggul Wibawa, R. Hasanah, H. Suyono","doi":"10.1109/ICHVEPS47643.2019.9011086","DOIUrl":null,"url":null,"abstract":"This paper describes the results of research on the effect of profile factor on leakage current of four types of 20kV-post insulators in dry and wet clean conditions. The high ac voltage applied to the post insulator during experiment was 25kV corresponding to the highest voltage on a 20kV system. The level of insulator wetting has been referred to the average daily rainfall data in Indonesia. Three common rainfall values have been considered, namely 20mm, 50mm and 100mm, which are equivalent to the amount of watering level of 16ml/s, 30ml/s, and 60ml/s respectively. The results showed the significant effect of profile factor on the level of leakage current of post insulator both in clean dry and wet conditions.","PeriodicalId":6677,"journal":{"name":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","volume":"30 1","pages":"186-189"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVEPS47643.2019.9011086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the results of research on the effect of profile factor on leakage current of four types of 20kV-post insulators in dry and wet clean conditions. The high ac voltage applied to the post insulator during experiment was 25kV corresponding to the highest voltage on a 20kV system. The level of insulator wetting has been referred to the average daily rainfall data in Indonesia. Three common rainfall values have been considered, namely 20mm, 50mm and 100mm, which are equivalent to the amount of watering level of 16ml/s, 30ml/s, and 60ml/s respectively. The results showed the significant effect of profile factor on the level of leakage current of post insulator both in clean dry and wet conditions.
不同外形系数下配电柱绝缘子上的泄漏电流
本文介绍了在干湿清洁条件下,对4种20kv柱式绝缘子外形因子对漏电电流影响的研究结果。实验过程中施加在柱绝缘子上的高交流电压为25kV,对应20kV系统上的最高电压。绝缘体润湿水平参考了印度尼西亚的平均日降雨量数据。我们考虑了三种常见的降雨值,分别为20mm、50mm和100mm,分别相当于16ml/s、30ml/s和60ml/s的水量。结果表明,在干湿两种工况下,外形因子对柱式绝缘子的漏电流水平均有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信