Johannes M. Eckhardt, Tobias Doeker, S. Rey, T. Kürner
{"title":"Measurements in a Real Data Centre at 300 GHz and Recent Results","authors":"Johannes M. Eckhardt, Tobias Doeker, S. Rey, T. Kürner","doi":"10.24355/DBBS.084-201908301357-0","DOIUrl":null,"url":null,"abstract":"In this paper a measurement campaign in a real Data Centre at 300 GHz and recent results are presented. The measurements are performed with a UWB sub-mmWave channel sounder and classified in general characterisation, top-of-rack and intra-rack measurements. The individual measurement setups as well as the methodology are explained. In a first step, the measurements are evaluated regarding the path attenuation, the power delay profile (PDP) and the power angular spectrum (PAS). The PDP as well as the PAS give comprehensible results, which are explained by the scenario’s geometry. The path attenuation shows reasonable results compared to the free space path loss and demonstrates that wireless communication at 300 GHz in a Data Centre is possible.","PeriodicalId":6612,"journal":{"name":"2019 13th European Conference on Antennas and Propagation (EuCAP)","volume":"8 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"49","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 13th European Conference on Antennas and Propagation (EuCAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24355/DBBS.084-201908301357-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 49
Abstract
In this paper a measurement campaign in a real Data Centre at 300 GHz and recent results are presented. The measurements are performed with a UWB sub-mmWave channel sounder and classified in general characterisation, top-of-rack and intra-rack measurements. The individual measurement setups as well as the methodology are explained. In a first step, the measurements are evaluated regarding the path attenuation, the power delay profile (PDP) and the power angular spectrum (PAS). The PDP as well as the PAS give comprehensible results, which are explained by the scenario’s geometry. The path attenuation shows reasonable results compared to the free space path loss and demonstrates that wireless communication at 300 GHz in a Data Centre is possible.