{"title":"Fire Testing of Valve and Wellhead Equipment to API Specifications","authors":"W. L. Guice, T. L. Shinn","doi":"10.2118/20880-PA","DOIUrl":null,"url":null,"abstract":"Mathematical modeling and test data were used to predict the temperatures of valve and wellhead equipment in API fire testing. This paper reports that the thermal response of these systems is used to select critical parts for fire-resistant equipment. Conditions of internal components were found to be calculable on the basis of defined test criteria.","PeriodicalId":22020,"journal":{"name":"Spe Production Engineering","volume":"4 1","pages":"107-112"},"PeriodicalIF":0.0000,"publicationDate":"1992-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spe Production Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/20880-PA","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Mathematical modeling and test data were used to predict the temperatures of valve and wellhead equipment in API fire testing. This paper reports that the thermal response of these systems is used to select critical parts for fire-resistant equipment. Conditions of internal components were found to be calculable on the basis of defined test criteria.