Rapid Nitrate Loss from PM10 Filters

C. Dunwoody
{"title":"Rapid Nitrate Loss from PM10 Filters","authors":"C. Dunwoody","doi":"10.1080/00022470.1986.10466118","DOIUrl":null,"url":null,"abstract":"As part of the California Air Resources Board's ongoing laboratory quality control and method validation program, researchers conducted comparative measurements of PM/sub 10/ nitrate and sulfate concentrations to demonstrate the equivalency of analytical procedures used in different laboratories. Surprisingly, the nitrate values measured after the six to eight months interim averaged 86% lower than those previously reported. The sulfate values stayed the same. This paper examines this rapid loss of nitrate from the PM/sub 10/ filters and the problems associated with using this method of measuring atmospheric nitrate.","PeriodicalId":17188,"journal":{"name":"Journal of the Air Pollution Control Association","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1986-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air Pollution Control Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00022470.1986.10466118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

As part of the California Air Resources Board's ongoing laboratory quality control and method validation program, researchers conducted comparative measurements of PM/sub 10/ nitrate and sulfate concentrations to demonstrate the equivalency of analytical procedures used in different laboratories. Surprisingly, the nitrate values measured after the six to eight months interim averaged 86% lower than those previously reported. The sulfate values stayed the same. This paper examines this rapid loss of nitrate from the PM/sub 10/ filters and the problems associated with using this method of measuring atmospheric nitrate.
PM10过滤器快速硝酸盐损失
作为加州空气资源委员会正在进行的实验室质量控制和方法验证项目的一部分,研究人员进行了PM/sub - 10/硝酸盐和硫酸盐浓度的比较测量,以证明不同实验室使用的分析方法的等效性。令人惊讶的是,6到8个月后测量的硝酸盐值平均比之前报道的低86%。硫酸盐值保持不变。本文研究了PM/sub - 10/过滤器中硝酸盐的快速损失,以及使用这种方法测量大气硝酸盐的相关问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信