Research and development of combined universal cement mortar admixture

IF 0.3 Q4 ENGINEERING, PETROLEUM
Nafta-Gaz Pub Date : 2023-02-01 DOI:10.18668/ng.2023.02.04
Eldar M. Suleymanov, Rafiq S. Ibrahimov, S. Novruzova, Shirin O. Bahshaliyeva
{"title":"Research and development of combined universal cement mortar admixture","authors":"Eldar M. Suleymanov, Rafiq S. Ibrahimov, S. Novruzova, Shirin O. Bahshaliyeva","doi":"10.18668/ng.2023.02.04","DOIUrl":null,"url":null,"abstract":"Due to the wide variety of drilling and cementing conditions, different grades of cements for different conditions need to be produced by factories. Nowadays, with the development of test methods and techniques, additional materials and substances, the trend has been to focus on some basic cement (base), which, with various additional substances or materials, can be modified according to the conditions of use. According to the technology adopted in Schlumberger, two portions of cement slurry are mainly used for the entire length of the annulus “lead” and “tail” i.e. literally the “leader” (the first portion) and the “tail’ (the second, last portion). Of course, the treatment of these portions with chemical reagents is different, and the first portion is several times larger in volume than the second portion. It is known that as a result of unsuccessful cementing, a gas-water-oil show may appear, leading to the removal of casing strings, fire, etc. As a result, this leads to the abandonment of the well. There is a time difference between the mixing of the first and subsequent portions of dry cement, especially the last ones, since while the subsequent portions of dry cement are just being mixed, the freshest ones have not yet been mixed at all, but the first portions are already finished; this portion of cement slurry in the well gradually begins to thicken under the influence of temperature and pressure. An effective reagent is needed. The optimal composition of the combined reagent should be considered as follows: CMC – 0.2%; FLS – 0.4%; Na2CO3 – 0.05%.","PeriodicalId":45266,"journal":{"name":"Nafta-Gaz","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nafta-Gaz","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18668/ng.2023.02.04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, PETROLEUM","Score":null,"Total":0}
引用次数: 0

Abstract

Due to the wide variety of drilling and cementing conditions, different grades of cements for different conditions need to be produced by factories. Nowadays, with the development of test methods and techniques, additional materials and substances, the trend has been to focus on some basic cement (base), which, with various additional substances or materials, can be modified according to the conditions of use. According to the technology adopted in Schlumberger, two portions of cement slurry are mainly used for the entire length of the annulus “lead” and “tail” i.e. literally the “leader” (the first portion) and the “tail’ (the second, last portion). Of course, the treatment of these portions with chemical reagents is different, and the first portion is several times larger in volume than the second portion. It is known that as a result of unsuccessful cementing, a gas-water-oil show may appear, leading to the removal of casing strings, fire, etc. As a result, this leads to the abandonment of the well. There is a time difference between the mixing of the first and subsequent portions of dry cement, especially the last ones, since while the subsequent portions of dry cement are just being mixed, the freshest ones have not yet been mixed at all, but the first portions are already finished; this portion of cement slurry in the well gradually begins to thicken under the influence of temperature and pressure. An effective reagent is needed. The optimal composition of the combined reagent should be considered as follows: CMC – 0.2%; FLS – 0.4%; Na2CO3 – 0.05%.
复合型万能水泥砂浆外加剂的研究与开发
由于钻井和固井条件的多样性,需要工厂生产适合不同条件的不同牌号的水泥。如今,随着测试方法和技术、附加材料和物质的发展,趋势已经集中在一些基础水泥(基)上,这些水泥(基)在加入各种附加物质或材料后,可以根据使用条件进行改性。根据斯伦贝谢采用的技术,整个环空“先导”和“尾”主要使用两部分水泥浆,即字面上的“先导”(第一部分)和“尾”(第二部分,最后一部分)。当然,这些部分用化学试剂处理是不同的,第一部分的体积比第二部分大几倍。众所周知,由于固井不成功,可能会出现气-水-油现象,导致套管柱脱落、火灾等。因此,这将导致弃井。第一批干水泥与后续干水泥,特别是最后一批干水泥的混合存在时间差,因为当后续干水泥刚刚混合时,最新鲜的干水泥还没有混合,但第一批干水泥已经完成;井内这部分水泥浆在温度和压力的作用下逐渐开始变稠。需要一种有效的试剂。组合试剂的最佳组成应考虑如下:CMC - 0.2%;FLS - 0.4%;Na2CO3 - 0.05%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nafta-Gaz
Nafta-Gaz ENGINEERING, PETROLEUM-
CiteScore
0.80
自引率
60.00%
发文量
81
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信