Simultaneous Detection of Drug-Induced Liver Injury Protein and microRNA Biomarkers Using Dynamic Chemical Labelling on a Luminex MAGPIX System

Analytica Pub Date : 2021-10-03 DOI:10.3390/analytica2040013
Antonio Marín-Romero, Mavys Tabraue-Chávez, Bárbara López-Longarela, M. A. Fara, R. Sánchez-Martín, J. Dear, Hugh Ilyine, J. Díaz-Mochón, Salvatore Pernagallo
{"title":"Simultaneous Detection of Drug-Induced Liver Injury Protein and microRNA Biomarkers Using Dynamic Chemical Labelling on a Luminex MAGPIX System","authors":"Antonio Marín-Romero, Mavys Tabraue-Chávez, Bárbara López-Longarela, M. A. Fara, R. Sánchez-Martín, J. Dear, Hugh Ilyine, J. Díaz-Mochón, Salvatore Pernagallo","doi":"10.3390/analytica2040013","DOIUrl":null,"url":null,"abstract":"Drug-induced liver injury (DILI) is a potentially fatal adverse event and a leading cause for pre- and post-marketing drug withdrawal. Several multinational DILI initiatives have now recommended a panel of protein and microRNA (miRNA) biomarkers that can detect early liver injury and inform about mechanistic basis. This manuscript describes the development of seqCOMBO, a unique combo-multiplexed assay which combines the dynamic chemical labelling approach and an antibody-dependant method on the Luminex MAGPIX system. SeqCOMBO enables a versatile multiplexing platform to perform qualitative and quantitative analysis of proteins and miRNAs in patient serum samples simultaneously. To the best of our knowledge, this is the first method to profile protein and miRNA biomarkers to diagnose DILI in a single-step assay.","PeriodicalId":7829,"journal":{"name":"Analytica","volume":"45 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/analytica2040013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Drug-induced liver injury (DILI) is a potentially fatal adverse event and a leading cause for pre- and post-marketing drug withdrawal. Several multinational DILI initiatives have now recommended a panel of protein and microRNA (miRNA) biomarkers that can detect early liver injury and inform about mechanistic basis. This manuscript describes the development of seqCOMBO, a unique combo-multiplexed assay which combines the dynamic chemical labelling approach and an antibody-dependant method on the Luminex MAGPIX system. SeqCOMBO enables a versatile multiplexing platform to perform qualitative and quantitative analysis of proteins and miRNAs in patient serum samples simultaneously. To the best of our knowledge, this is the first method to profile protein and miRNA biomarkers to diagnose DILI in a single-step assay.
在Luminex MAGPIX系统上使用动态化学标记同时检测药物性肝损伤蛋白和microRNA生物标志物
药物性肝损伤(DILI)是一种潜在的致命不良事件,也是上市前和上市后药物停药的主要原因。几个多国DILI倡议现在推荐了一组蛋白质和microRNA (miRNA)生物标志物,可以检测早期肝损伤并提供机制基础。这篇手稿描述了seqCOMBO的发展,这是一种独特的组合多路分析,结合了动态化学标记方法和Luminex MAGPIX系统上的抗体依赖方法。SeqCOMBO是一个多功能的多路复用平台,可以同时对患者血清样本中的蛋白质和mirna进行定性和定量分析。据我们所知,这是第一个通过单步分析分析蛋白质和miRNA生物标志物来诊断DILI的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信