INFLUENCE OF MILLIMETER RANGE ELECTROMAGNETIC WAVES ON HEMOLYSIS KINETICS OF RAT BLOOD ERYTHROCYTES

M. Shahinyan, M. Mikaelyan, A. Nerkararyan
{"title":"INFLUENCE OF MILLIMETER RANGE ELECTROMAGNETIC WAVES ON HEMOLYSIS KINETICS OF RAT BLOOD ERYTHROCYTES","authors":"M. Shahinyan, M. Mikaelyan, A. Nerkararyan","doi":"10.46991/pysu:b/2020.54.3.209","DOIUrl":null,"url":null,"abstract":"The effect of millimeter range electromagnetic waves (MM EMW) on kinetics of acidic hemolysis of rat blood erythrocytes has been studied. It was shown that MM EMW affect the duration of erythrocyte hemolysis and this change depends on MM EMW exposure and frequency. At the irradiation by frequencies 41.8 and 42.2 GHz the acidic hemolysis occurs quicker at all durations of the irradiation compared to the control. At the irradiation by 50.3 and 51.8 GHz the hemolysis takes place quicker as well, as compared to the control at short durations of the irradiation. At the exposure 60 min the hemolysis start is delayed.","PeriodicalId":20692,"journal":{"name":"Proceedings of the YSU B: Chemical and Biological Sciences","volume":"16 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the YSU B: Chemical and Biological Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46991/pysu:b/2020.54.3.209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The effect of millimeter range electromagnetic waves (MM EMW) on kinetics of acidic hemolysis of rat blood erythrocytes has been studied. It was shown that MM EMW affect the duration of erythrocyte hemolysis and this change depends on MM EMW exposure and frequency. At the irradiation by frequencies 41.8 and 42.2 GHz the acidic hemolysis occurs quicker at all durations of the irradiation compared to the control. At the irradiation by 50.3 and 51.8 GHz the hemolysis takes place quicker as well, as compared to the control at short durations of the irradiation. At the exposure 60 min the hemolysis start is delayed.
毫米波对大鼠红细胞溶血动力学的影响
研究了毫米波对大鼠红细胞酸性溶血动力学的影响。结果表明,mmemw会影响红细胞溶血的持续时间,这种变化取决于mmemw暴露和频率。在频率为41.8 GHz和42.2 GHz的照射下,酸性溶血在所有照射时间内都比对照组发生得更快。在50.3 GHz和51.8 GHz的照射下,溶血也比在短时间照射下的对照组发生得更快。暴露60分钟后,溶血开始延迟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信