Use of high surface area TiO$_2$ for preconcentration and following determination of Cr species by on-line flow injection inductively coupled plasma atomic emission spectrometry
{"title":"Use of high surface area TiO$_2$ for preconcentration and following determination of Cr species by on-line flow injection inductively coupled plasma atomic emission spectrometry","authors":"E. Vassileva","doi":"10.1051/ANALUSIS:2000160","DOIUrl":null,"url":null,"abstract":"A flow-injection analysis (FIA) system incorporating two microcolumns of TiO 2 was used for the developing of an on- line method for preconcentration and sequential determination of Cr 3+ and Cr6+ species by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for both analytes have been obtained. With a sample volume of 10-50 ml and an elution volume of 500 µl, a signal was 20-100 times higher than the signal given by a continuous aspiration system. The method gave good reproducibility with precisions less than 7 % RSD for 5 replicates at the 10 ng/ml level for both Cr- species. Recoveries between 95 and 98 % were obtained for Cr 3+ and Cr6+. The preconcentration system and the methodology proposed were validated on several natural water samples, on reference water samples as well as on synthetic seawater. It was found that the on-line detection using ICP-AES allows sequential Cr speciation analysis at the low concentration levels (ng/l) usually encountered in these media.","PeriodicalId":8221,"journal":{"name":"Analusis","volume":"40 1","pages":"878-884"},"PeriodicalIF":0.0000,"publicationDate":"2000-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analusis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ANALUSIS:2000160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
A flow-injection analysis (FIA) system incorporating two microcolumns of TiO 2 was used for the developing of an on- line method for preconcentration and sequential determination of Cr 3+ and Cr6+ species by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for both analytes have been obtained. With a sample volume of 10-50 ml and an elution volume of 500 µl, a signal was 20-100 times higher than the signal given by a continuous aspiration system. The method gave good reproducibility with precisions less than 7 % RSD for 5 replicates at the 10 ng/ml level for both Cr- species. Recoveries between 95 and 98 % were obtained for Cr 3+ and Cr6+. The preconcentration system and the methodology proposed were validated on several natural water samples, on reference water samples as well as on synthetic seawater. It was found that the on-line detection using ICP-AES allows sequential Cr speciation analysis at the low concentration levels (ng/l) usually encountered in these media.