Improved Load Transient Response of a Dual-Active-Bridge Converter

Shengzhi Zhou, Chuan Sun, Song Hu, Guo-Tian Chen, Xiaodong Li
{"title":"Improved Load Transient Response of a Dual-Active-Bridge Converter","authors":"Shengzhi Zhou, Chuan Sun, Song Hu, Guo-Tian Chen, Xiaodong Li","doi":"10.23919/IPEC.2018.8507881","DOIUrl":null,"url":null,"abstract":"In this work, the transient response of a dual-active-bridge (DAB) converter to load-change command is investigated under dual-phase-shift (DPS) control. During the transient process, there might be dc bias current and overshoot current arising in the inductor and transformer due to improper transient modulation. A dedicated transient modulation method is then proposed, which adjusts all phase-shift ratios by referring to a floating reference gating signal. Consequently a fast transient response can be obtained without dc bias current and overshoot current. The dynamic movement of the floating reference signal can be determined easily by a uniformed expression irrespective of the different steady state operation modes. The proposed transient control has been proved through simulation and experimental results.","PeriodicalId":6610,"journal":{"name":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","volume":" 1","pages":"370-374"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/IPEC.2018.8507881","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

In this work, the transient response of a dual-active-bridge (DAB) converter to load-change command is investigated under dual-phase-shift (DPS) control. During the transient process, there might be dc bias current and overshoot current arising in the inductor and transformer due to improper transient modulation. A dedicated transient modulation method is then proposed, which adjusts all phase-shift ratios by referring to a floating reference gating signal. Consequently a fast transient response can be obtained without dc bias current and overshoot current. The dynamic movement of the floating reference signal can be determined easily by a uniformed expression irrespective of the different steady state operation modes. The proposed transient control has been proved through simulation and experimental results.
改进的双有源桥式变换器负载瞬态响应
本文研究了双相移(DPS)控制下双有源桥式(DAB)变换器对负载变化命令的瞬态响应。在暂态过程中,由于暂态调制不当,可能会在电感和变压器中产生直流偏置电流和超调电流。然后提出了一种专用的瞬态调制方法,该方法通过参考浮动基准门控信号来调整所有相移比。因此,可以获得快速的瞬态响应,没有直流偏置电流和超调电流。在不同的稳态工作模式下,浮动参考信号的动态运动可以很容易地用一个统一的表达式来确定。仿真和实验结果验证了所提出的暂态控制方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信