10B-3 Vibrating Interventional Device Detection Using Real-Time 3D Color Doppler

M. Fronheiser, S. Idriss, P. Wolf, S.W. Smith
{"title":"10B-3 Vibrating Interventional Device Detection Using Real-Time 3D Color Doppler","authors":"M. Fronheiser, S. Idriss, P. Wolf, S.W. Smith","doi":"10.1109/ULTSYM.2007.222","DOIUrl":null,"url":null,"abstract":"We have previously described guidance of several interventional devices using a real time 3D (RT3D) ultrasound system with 3D color Doppler combined with the ColorMark technology. We then developed an analytical model for a vibrating needle to maximize the tip vibrations and improve the reliability and sensitivity of our technique. In this work, we use the analytical model and improved radiofrequency (RF) and color Doppler filters to detect two different vibrating devices in water tank experiments as well as in an in vivo canine experiment. An atrial septal puncture needle and an endomyocardial biopsy forceps, each vibrating at 1.3 kHz, were inserted into the vascular graft and were tracked using 3D color Doppler. Improved RF and wall filters increased the detected color Doppler sensitivity by 14 dB. In three simultaneous planes from the in vivo 3D scan, we identified both the septal puncture needle and the biopsy forceps within the right atrium using the 2.5 MHz probe. A display filter was used to suppress the unwanted flash artifact associated with physiological motion.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"1 1","pages":"868-871"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We have previously described guidance of several interventional devices using a real time 3D (RT3D) ultrasound system with 3D color Doppler combined with the ColorMark technology. We then developed an analytical model for a vibrating needle to maximize the tip vibrations and improve the reliability and sensitivity of our technique. In this work, we use the analytical model and improved radiofrequency (RF) and color Doppler filters to detect two different vibrating devices in water tank experiments as well as in an in vivo canine experiment. An atrial septal puncture needle and an endomyocardial biopsy forceps, each vibrating at 1.3 kHz, were inserted into the vascular graft and were tracked using 3D color Doppler. Improved RF and wall filters increased the detected color Doppler sensitivity by 14 dB. In three simultaneous planes from the in vivo 3D scan, we identified both the septal puncture needle and the biopsy forceps within the right atrium using the 2.5 MHz probe. A display filter was used to suppress the unwanted flash artifact associated with physiological motion.
10B-3振动介入装置的实时三维彩色多普勒检测
我们之前描述了几种使用实时3D (RT3D)超声系统与3D彩色多普勒结合ColorMark技术的介入设备的指导。然后,我们开发了一个振动针的分析模型,以最大限度地提高尖端振动,提高我们技术的可靠性和灵敏度。在这项工作中,我们使用分析模型和改进的射频(RF)和彩色多普勒滤波器在水箱实验和犬体内实验中检测两种不同的振动装置。房间隔穿刺针和心内膜活检钳分别以1.3 kHz振动插入血管移植物,并使用3D彩色多普勒进行跟踪。改进的射频和壁滤波器使检测到的彩色多普勒灵敏度提高了14 dB。在体内三维扫描的三个同步平面上,我们使用2.5 MHz探针在右心房内确定了室间隔穿刺针和活检钳。使用显示滤波器来抑制与生理运动相关的不必要的闪光伪影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信