The impact of different augmentative methods on the expression of inflammatory factors.

Marcus Stoetzer, Vasilios Alevizakos, B. Rahlf, N. Gellrich, A. Kampmann, C. von See
{"title":"The impact of different augmentative methods on the expression of inflammatory factors.","authors":"Marcus Stoetzer, Vasilios Alevizakos, B. Rahlf, N. Gellrich, A. Kampmann, C. von See","doi":"10.1563/aaid-joi-D-19-00050","DOIUrl":null,"url":null,"abstract":"Many animal studies show that an intact periosteum plays an important role in osseous regeneration. The potential effect of an in vivo periosteal barrier membrane on the expression of specific proteins has not been examined sufficiently. The aim of the present study is to investigate the influence of flap preparation method and collagen membrane on the emission of inflammatory factors. This study examines 20 patients with dental implants who had previously undergone an augmentation. A soft tissue sample was taken during augmentation and three months later from the same location. Samples were always taken from the margins of a previously prepared mucoperiosteal flap. The flap was raised with a conventional periosteal elevator in the control group and with a piezoelectric device in the test group. In both groups, we covered half of the augmented bone with a native collagen membrane (NCM; Geistlich Bio-Gide). This allowed us to examine the same incision area with and without a membrane. An immunohistochemical analysis was performed for collagen IV, fibronectin and inflammatory factors such asCD31, COX-2 and IL-6.  There was a clear difference in the expression of specific proteins after the piezoelectric device and the periosteal elevator were used. The expression of fibronectin, IL-6 and COX-2 was higher after preparation with the periosteal elevator than after piezoelectric periosteum dissection. The expression of collagen IV was higher after the piezoelectric procedure. No difference was observed for CD31. The membrane had no effect on the expression of collagen IV, fibronectin, IL-6 and COX-2. The type of periosteal preparation influences the expression of specific proteins. With regard to the factors examined here, NCM did not appear to influence the wound healing cascade.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":" 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1563/aaid-joi-D-19-00050","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-19-00050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Many animal studies show that an intact periosteum plays an important role in osseous regeneration. The potential effect of an in vivo periosteal barrier membrane on the expression of specific proteins has not been examined sufficiently. The aim of the present study is to investigate the influence of flap preparation method and collagen membrane on the emission of inflammatory factors. This study examines 20 patients with dental implants who had previously undergone an augmentation. A soft tissue sample was taken during augmentation and three months later from the same location. Samples were always taken from the margins of a previously prepared mucoperiosteal flap. The flap was raised with a conventional periosteal elevator in the control group and with a piezoelectric device in the test group. In both groups, we covered half of the augmented bone with a native collagen membrane (NCM; Geistlich Bio-Gide). This allowed us to examine the same incision area with and without a membrane. An immunohistochemical analysis was performed for collagen IV, fibronectin and inflammatory factors such asCD31, COX-2 and IL-6.  There was a clear difference in the expression of specific proteins after the piezoelectric device and the periosteal elevator were used. The expression of fibronectin, IL-6 and COX-2 was higher after preparation with the periosteal elevator than after piezoelectric periosteum dissection. The expression of collagen IV was higher after the piezoelectric procedure. No difference was observed for CD31. The membrane had no effect on the expression of collagen IV, fibronectin, IL-6 and COX-2. The type of periosteal preparation influences the expression of specific proteins. With regard to the factors examined here, NCM did not appear to influence the wound healing cascade.
不同增强方法对炎性因子表达的影响。
许多动物研究表明,完整的骨膜在骨再生中起着重要作用。体内骨膜屏障膜对特定蛋白表达的潜在影响尚未得到充分研究。本研究旨在探讨皮瓣制备方法和胶原膜对炎症因子释放的影响。本研究调查了20名曾接受过隆胸手术的植牙患者。在增强期间和三个月后从同一位置采集软组织样本。样本总是取自先前制备的粘骨膜瓣的边缘。对照组用常规骨膜提升器提起皮瓣,试验组用压电装置提起皮瓣。在两组中,我们用天然胶原膜(NCM)覆盖一半的增强骨;Geistlich Bio-Gide)。这使我们能够检查有膜和没有膜的同一切口区域。免疫组化分析IV型胶原蛋白、纤维连接蛋白和炎性因子如cd31、COX-2和IL-6。使用压电装置和骨膜提升器后,特异蛋白的表达有明显差异。骨膜提升器制备后纤维连接蛋白、IL-6和COX-2的表达高于压电式骨膜剥离后。压电处理后,IV型胶原蛋白的表达较高。CD31未见差异。膜对IV型胶原、纤维连接蛋白、IL-6和COX-2的表达无影响。骨膜制备的类型影响特定蛋白的表达。关于这里检查的因素,NCM似乎不影响伤口愈合级联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书