{"title":"Fault Tolerant Inverter for Grid Connected Photovoltaic System","authors":"A. Malik, Ahteshamul Haque, K. V. Satya Bharath","doi":"10.1109/PESGRE52268.2022.9715825","DOIUrl":null,"url":null,"abstract":"With the increased focus on grid connected Photovoltaic (PV) systems, the reliability and stability of grid-connected inverters is a major area of interest. The occurrence of fault in any part of the inverter may severely impact the system leading to adverse effects at the grid end. To improve the system reliability, it is imperative to equip the system with fault tolerant scheme that can handle such failure conditions and prevents the system from shutting down. This paper proposes parallel inverter-based fault tolerant technique for single-phase grid-integrated PV Inverters. It realizes simple fault diagnostic technique for fault identification. After that faulty part is isolated and reconfiguration takes place. The proposed fault tolerant mechanism is validated by performing numerical simulations in MATLAB/Simulink environment. The simulation results verify the potential of the presented technique in dealing with fault conditions.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"智能电网与可再生能源(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/PESGRE52268.2022.9715825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

With the increased focus on grid connected Photovoltaic (PV) systems, the reliability and stability of grid-connected inverters is a major area of interest. The occurrence of fault in any part of the inverter may severely impact the system leading to adverse effects at the grid end. To improve the system reliability, it is imperative to equip the system with fault tolerant scheme that can handle such failure conditions and prevents the system from shutting down. This paper proposes parallel inverter-based fault tolerant technique for single-phase grid-integrated PV Inverters. It realizes simple fault diagnostic technique for fault identification. After that faulty part is isolated and reconfiguration takes place. The proposed fault tolerant mechanism is validated by performing numerical simulations in MATLAB/Simulink environment. The simulation results verify the potential of the presented technique in dealing with fault conditions.
并网光伏系统容错逆变器
随着人们对并网光伏系统的关注日益增加,并网逆变器的可靠性和稳定性成为人们关注的主要领域。逆变器的任何一个部位出现故障,都可能对系统造成严重影响,导致电网端出现不良影响。为了提高系统的可靠性,必须为系统配备容错方案,以应对这种故障情况,防止系统停机。提出了基于并联逆变器的单相并网光伏逆变器容错技术。实现了简单的故障诊断技术,用于故障识别。在故障部件被隔离并重新配置之后。在MATLAB/Simulink环境下进行了数值仿真,验证了所提出的容错机制。仿真结果验证了该方法在处理故障条件方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
307
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信