L. H. Moreira, M. K. Salomão, H. C. Carvalho, André Luis Silva Mendes, R. A. Zângaro, A. B. Fernandes, Carlos José de Lima
{"title":"Ozonation of Bovine Peritoneal Membrane for Preservation: Preliminary Investigation","authors":"L. H. Moreira, M. K. Salomão, H. C. Carvalho, André Luis Silva Mendes, R. A. Zângaro, A. B. Fernandes, Carlos José de Lima","doi":"10.1080/01919512.2021.1984205","DOIUrl":null,"url":null,"abstract":"ABSTRACT A dynamic fluid system using ozonated water flowing over the bovine peritoneal membrane was developed. Histological analyses were performed to verify the maximum time of ozone exposure to maintain the viability of the biological material. The results indicate that the biological viability of the peritoneum tissue was impaired after 15 minutes of exposure (5.5 mg O3 (cm2)−1) to ozonated water in a dynamic condition. Thus, this biological sample can be submitted to the dynamic fluid system with ozonated water for 10 minutes at an applied ozone dose of 3.7 mg O3 (cm2)−1, without inducing significant changes to the tissue.","PeriodicalId":19580,"journal":{"name":"Ozone: Science & Engineering","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2021-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ozone: Science & Engineering","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/01919512.2021.1984205","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 3
Abstract
ABSTRACT A dynamic fluid system using ozonated water flowing over the bovine peritoneal membrane was developed. Histological analyses were performed to verify the maximum time of ozone exposure to maintain the viability of the biological material. The results indicate that the biological viability of the peritoneum tissue was impaired after 15 minutes of exposure (5.5 mg O3 (cm2)−1) to ozonated water in a dynamic condition. Thus, this biological sample can be submitted to the dynamic fluid system with ozonated water for 10 minutes at an applied ozone dose of 3.7 mg O3 (cm2)−1, without inducing significant changes to the tissue.
期刊介绍:
The only journal in the world that focuses on the technologies of ozone and related oxidation technologies, Ozone: Science and Engineering brings you quality original research, review papers, research notes, and case histories in each issue. Get the most up-to date results of basic, applied, and engineered research including:
-Ozone generation and contacting-
Treatment of drinking water-
Analysis of ozone in gases and liquids-
Treatment of wastewater and hazardous waste-
Advanced oxidation processes-
Treatment of emerging contaminants-
Agri-Food applications-
Process control of ozone systems-
New applications for ozone (e.g. laundry applications, semiconductor applications)-
Chemical synthesis.
All submitted manuscripts are subject to initial appraisal by the Editor, and, if found suitable for further consideration, to peer review by independent, anonymous expert referees.