{"title":"Generator Life and Power Electronics","authors":"KENT R. DAVEY,&nbsp;HOWARD E. JORDAN,&nbsp;RIGOBERTO J. RODRIGUEZ,&nbsp;ROBERT E. HEBNER","doi":"10.1111/j.1559-3584.2011.00193.x","DOIUrl":null,"url":null,"abstract":"<p>The deleterious effect of full bridge rectifiers on the output of an AC generator deserves attention from the Naval community. The harmonics observed at the stator of the generator not only introduce hysteresis and eddy current losses, but voltage spikes that impact the life of the generator. The two primary factors compromising life are localized heating due to harmonics and voltage spikes that cause insulation failure through partial discharge. Induced eddy currents are proportional to frequency squared.</p>","PeriodicalId":49775,"journal":{"name":"Naval Engineers Journal","volume":"123 4","pages":"31-39"},"PeriodicalIF":0.2000,"publicationDate":"2012-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1559-3584.2011.00193.x","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Naval Engineers Journal","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/j.1559-3584.2011.00193.x","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 2

Abstract

The deleterious effect of full bridge rectifiers on the output of an AC generator deserves attention from the Naval community. The harmonics observed at the stator of the generator not only introduce hysteresis and eddy current losses, but voltage spikes that impact the life of the generator. The two primary factors compromising life are localized heating due to harmonics and voltage spikes that cause insulation failure through partial discharge. Induced eddy currents are proportional to frequency squared.

发电机寿命与电力电子
全桥整流器对交流发电机输出的有害影响值得海军界关注。在发电机定子处观察到的谐波不仅会产生磁滞和涡流损耗,还会产生影响发电机寿命的电压尖峰。影响寿命的两个主要因素是谐波和电压尖峰引起的局部加热,这些因素会通过局部放电导致绝缘失效。感应涡流与频率平方成正比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Naval Engineers Journal
Naval Engineers Journal 工程技术-工程:海洋
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信