Localized corrosion promoted by protective coatings on ARMCO iron in deaerated acid solutions

E. Soragni, G. Davolio
{"title":"Localized corrosion promoted by protective coatings on ARMCO iron in deaerated acid solutions","authors":"E. Soragni,&nbsp;G. Davolio","doi":"10.1016/0390-6035(82)90085-2","DOIUrl":null,"url":null,"abstract":"<div><p>The screening effects of some insulating materials like Nylon 66, PTFE and PVC had been tested in corrosion processes of carbon steels with different carbon contents and of ARMCO Iron in deaerated acid solutions showing that all the types of screen in all the experimental conditions induce a fast process of localized corrosion at the three phases contact metal-screen-solution and that the attack morphology depends on geometry contact.</p><p>Also the varnishes up to now tested on ARMCO Iron, exhibit the same behaviour except a glycerophtalic Pb<sub>3</sub>O<sub>4</sub> charged resin. The generality of this phenomenon has led to formulate the hypothesys that the activation of the localized corrosion process may be due to the interaction of double layers generated in the solution by the metal and by the insulating material. The electrochemical experiments have shown a correlation among the ratio of the coated surface perimeter to the exposed surface area and the electrode potential, the current density and the polarization resistance.</p></div>","PeriodicalId":18221,"journal":{"name":"Materials Chemistry","volume":"7 2","pages":"Pages 265-275"},"PeriodicalIF":0.0000,"publicationDate":"1982-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0390-6035(82)90085-2","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0390603582900852","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The screening effects of some insulating materials like Nylon 66, PTFE and PVC had been tested in corrosion processes of carbon steels with different carbon contents and of ARMCO Iron in deaerated acid solutions showing that all the types of screen in all the experimental conditions induce a fast process of localized corrosion at the three phases contact metal-screen-solution and that the attack morphology depends on geometry contact.

Also the varnishes up to now tested on ARMCO Iron, exhibit the same behaviour except a glycerophtalic Pb3O4 charged resin. The generality of this phenomenon has led to formulate the hypothesys that the activation of the localized corrosion process may be due to the interaction of double layers generated in the solution by the metal and by the insulating material. The electrochemical experiments have shown a correlation among the ratio of the coated surface perimeter to the exposed surface area and the electrode potential, the current density and the polarization resistance.

保护涂层促进ARMCO铁在脱气酸溶液中的局部腐蚀
一些绝缘材料如尼龙66,PTFE和PVC在不同含碳量的碳钢和ARMCO铁在脱气酸溶液中的腐蚀过程中进行了测试,表明在所有实验条件下,所有类型的筛网在三相接触金属筛网溶液中都会引起快速的局部腐蚀过程,并且侵蚀形态取决于几何接触。此外,到目前为止,在ARMCO Iron上测试的清漆表现出相同的行为,除了甘油基Pb3O4充电树脂。这种现象的普遍性导致了局部腐蚀过程的激活可能是由于金属和绝缘材料在溶液中产生的双层相互作用。电化学实验表明,涂层表面周长与暴露表面积的比率与电极电势、电流密度和极化电阻之间存在相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信