Judith Finn RN, PhD (Commentary Author) , Ian Jacobs RN, PhD (Commentary Author)
{"title":"Survival of people with out-of-hospital cardiac arrest is not improved by equipping first responders with an automated external defibrillator","authors":"Judith Finn RN, PhD (Commentary Author) , Ian Jacobs RN, PhD (Commentary Author)","doi":"10.1016/j.ehbc.2004.03.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Question</h3><p>Will the use of automated external defibrillators by the police or firefighters result in better clinical outcomes for people with an out-of-hospital cardiac arrest?</p></div><div><h3>Study design</h3><p>Cross-over randomised controlled trial.</p></div><div><h3>Main results</h3><p>There was no significant difference in hospital discharge rates for people experiencing a cardiac arrest between areas in which firefighters and police officers were equipped with automated external defibrillators (AEDs) and those areas in which they were not (see Table 1). AEDs significantly improved the return of spontaneous circulation and admission to hospital.<span><div><div><table><tbody><tr><td><strong>Table 1</strong> Clinical outcomes by treatment group in people experiencing a cardiac arrest.</td></tr><tr><td>Outcome</td><td>AEDs used (n=243)</td><td>AEDs not used (n=226)</td><td>Odds ratio, AED used versus AED not used; (95% CI), P-value</td></tr><tr><td>Hospital discharge</td><td>44 (18%)</td><td>33 (15%)</td><td>1.3 (0.8 to 2.2), 0.33</td></tr><tr><td>Return of spontaneous circulation</td><td>139 (57%)</td><td>108 (48%)</td><td>1.5 (1.0 to 2.2), 0.05</td></tr><tr><td>Hospital admission</td><td>103 (42%)</td><td>74 (33%)</td><td>1.5 (1.1 to 1.6), 0.02</td></tr></tbody></table></div></div></span></p></div><div><h3>Authors’ conclusions</h3><p>Survival to hospital discharge in people experiencing an out-of-hospital cardiac arrest was not improved by equipping first responders with automated external defibrillators.</p></div>","PeriodicalId":100512,"journal":{"name":"Evidence-based Healthcare","volume":"8 3","pages":"Pages 139-141"},"PeriodicalIF":0.0000,"publicationDate":"2004-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ehbc.2004.03.012","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Evidence-based Healthcare","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1462941004000476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2004/4/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Question
Will the use of automated external defibrillators by the police or firefighters result in better clinical outcomes for people with an out-of-hospital cardiac arrest?
Study design
Cross-over randomised controlled trial.
Main results
There was no significant difference in hospital discharge rates for people experiencing a cardiac arrest between areas in which firefighters and police officers were equipped with automated external defibrillators (AEDs) and those areas in which they were not (see Table 1). AEDs significantly improved the return of spontaneous circulation and admission to hospital.
Table 1 Clinical outcomes by treatment group in people experiencing a cardiac arrest.
Outcome
AEDs used (n=243)
AEDs not used (n=226)
Odds ratio, AED used versus AED not used; (95% CI), P-value
Hospital discharge
44 (18%)
33 (15%)
1.3 (0.8 to 2.2), 0.33
Return of spontaneous circulation
139 (57%)
108 (48%)
1.5 (1.0 to 2.2), 0.05
Hospital admission
103 (42%)
74 (33%)
1.5 (1.1 to 1.6), 0.02
Authors’ conclusions
Survival to hospital discharge in people experiencing an out-of-hospital cardiac arrest was not improved by equipping first responders with automated external defibrillators.