Comparison of the effects of various lubricant eye drops on the in vitro rabbit corneal healing and toxicity

Q2 Medicine
R. Michael Dutescu, Claudia Panfil, Norbert Schrage
{"title":"Comparison of the effects of various lubricant eye drops on the in vitro rabbit corneal healing and toxicity","authors":"R. Michael Dutescu,&nbsp;Claudia Panfil,&nbsp;Norbert Schrage","doi":"10.1016/j.etp.2016.12.002","DOIUrl":null,"url":null,"abstract":"<div><p><span>Ingredients of lubricant eye drops are potentially harmful to the ocular surface<span>. The products Optive, Optive Fusion, Neopt<span> were tested regarding corneal irritability versus Vismed Multi and 0.01% benzalkonium chloride as negative and positive control, respectively. Formulas (30–40</span></span></span> <!-->μl per hour) were applied hourly in-vitro for six days on rabbit corneas (n<!--> <!-->=<!--> <span><span>5, per product) cultured in artificial anterior chambers (EVEIT system). Initially, four </span>corneal abrasions (2.4–4.6</span> <!-->mm<sup>2</sup><span><span>) were induced. All defects were monitored during drop application by fluorescein stains and </span>photographs. To ensure corneal vitality, glucose and lactate concentrations in artificial anterior chamber fluids were determined photometrically.</span></p><p>All products showed a complete corneal healing on day 2. Thereafter, all five Optive-treated corneas developed progressive fluorescein-positive epithelial lesions until day six (24.96<!--> <!-->μm, ±21.45<!--> <!-->μm, p<!--> <!-->&lt;<!--> <span>0.01). For Optive Fusion three corneas showed corneal erosions on day six (23.11</span> <!-->μm, ±37.02<!--> <!-->μm, p<!--> <!-->&gt;<!--> <span>0.5) while Vismed Multi did not adversely affect the corneal integrity. Glucose/lactate concentrations remained unchanged while lubricants<span> were applied. Histology revealed epithelial loss and severe alterations of the superficial stroma for Optive. Optive Fusion displayed a comparable pathology. Neopt did not significantly affect the corneal healing and integrity.</span></span></p><p>This study suggested a cumulative corneal toxicity of Optive and, to a lesser extent, Optive Fusion most likely caused by its oxidative preservative, SOC. Clinical data are needed to clarify the application frequency at which corneal toxicity might occur. Neopt and Vismed Multi did not affect the corneal integrity.</p></div>","PeriodicalId":50465,"journal":{"name":"Experimental and Toxicologic Pathology","volume":"69 3","pages":"Pages 123-129"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.etp.2016.12.002","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental and Toxicologic Pathology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S094029931630358X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 19

Abstract

Ingredients of lubricant eye drops are potentially harmful to the ocular surface. The products Optive, Optive Fusion, Neopt were tested regarding corneal irritability versus Vismed Multi and 0.01% benzalkonium chloride as negative and positive control, respectively. Formulas (30–40 μl per hour) were applied hourly in-vitro for six days on rabbit corneas (n = 5, per product) cultured in artificial anterior chambers (EVEIT system). Initially, four corneal abrasions (2.4–4.6 mm2) were induced. All defects were monitored during drop application by fluorescein stains and photographs. To ensure corneal vitality, glucose and lactate concentrations in artificial anterior chamber fluids were determined photometrically.

All products showed a complete corneal healing on day 2. Thereafter, all five Optive-treated corneas developed progressive fluorescein-positive epithelial lesions until day six (24.96 μm, ±21.45 μm, p < 0.01). For Optive Fusion three corneas showed corneal erosions on day six (23.11 μm, ±37.02 μm, p > 0.5) while Vismed Multi did not adversely affect the corneal integrity. Glucose/lactate concentrations remained unchanged while lubricants were applied. Histology revealed epithelial loss and severe alterations of the superficial stroma for Optive. Optive Fusion displayed a comparable pathology. Neopt did not significantly affect the corneal healing and integrity.

This study suggested a cumulative corneal toxicity of Optive and, to a lesser extent, Optive Fusion most likely caused by its oxidative preservative, SOC. Clinical data are needed to clarify the application frequency at which corneal toxicity might occur. Neopt and Vismed Multi did not affect the corneal integrity.

不同润滑剂滴眼液对兔角膜离体愈合及毒性的影响比较
润滑剂滴眼液的成分可能对眼表有害。Optive、Optive Fusion和Neopt产品分别与Vismed Multi和0.01%苯扎氯铵作为阴性和阳性对照进行角膜过敏性测试。在人工前房(EVEIT系统)中培养的兔角膜(每个产品n=5)上,每小时在体外应用配方奶粉(30–40μl/小时),持续6天。最初,诱发了四处角膜擦伤(2.4–4.6 mm2)。在滴涂过程中,通过荧光素染色和照片监测所有缺陷。为了确保角膜活力,用光度法测定了人工前房液中的葡萄糖和乳酸浓度。所有产品在第2天显示角膜完全愈合。此后,所有五个Optive治疗的角膜在第六天之前都出现了进行性荧光素阳性上皮病变(24.96μm,±21.45μm,p<;0.01)。对于Optive Fusion,三个角膜在第6天出现角膜侵蚀(23.11μm,?7.02μm,p>;0.5),而Vismed Multi没有对角膜完整性产生不利影响。使用润滑剂时,葡萄糖/乳酸浓度保持不变。组织学检查显示Optive的上皮缺失和浅层间质的严重改变。Optive Fusion显示了类似的病理学。Neopt对角膜愈合和完整性无明显影响。这项研究表明,Optive和Optive Fusion的累积角膜毒性在较小程度上很可能是由其氧化防腐剂SOC引起的。需要临床数据来阐明可能发生角膜毒性的应用频率。Neopt和Vismed Multi不影响角膜完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.08
自引率
0.00%
发文量
0
审稿时长
5.3 weeks
期刊介绍: Cessation. The international multidisciplinary journal is devoted to the publication of studies covering the whole range of experimental research on disease processes and toxicology including cell biological investigations. Its aim is to support progress in the interdisciplinary cooperation of researchers working in pathobiology, toxicology, and cell biology independent of the methods applied. During the past decades increasing attention has been paid to the importance of toxic influence in the pathogenesis of human and animal diseases. This is why Experimental and Toxicologic Pathology meets the urgent need for an interdisciplinary journal felt by a wide variety of experts in medicine and biology, including pathologists, toxicologists, biologists, physicians, veterinary surgeons, pharmacists, and pharmacologists working in academic, industrial or clinical institutions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信