Utilidad de la oclusión aórtica con balón REBOA para el control de las hemorragias puerperales en pacientes con anomalías de la implantación placentaria

IF 1.1 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
L. Fernández-Rodríguez, J. Novo Torres, M.D. Ponce Dorrego, R. Rodríguez Díaz, M.L. Collado Torres, G. Garzón Moll, T. Hernández Cabrero
{"title":"Utilidad de la oclusión aórtica con balón REBOA para el control de las hemorragias puerperales en pacientes con anomalías de la implantación placentaria","authors":"L. Fernández-Rodríguez,&nbsp;J. Novo Torres,&nbsp;M.D. Ponce Dorrego,&nbsp;R. Rodríguez Díaz,&nbsp;M.L. Collado Torres,&nbsp;G. Garzón Moll,&nbsp;T. Hernández Cabrero","doi":"10.1016/j.rx.2022.05.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and aims</h3><p>: Abnormalities of placental implantation, which make up the spectrum of placenta accreta, are associated with high maternal morbidity and mortality due to massive bleeding during delivery. Placing aortic occlusion balloons helps control the bleeding, facilitating surgical intervention. A new device, resuscitative endovascular balloon occlusion of the aorta (REBOA), minimizes the risks and complications associated with the placement of traditional aortic balloons and is also efficacious in controlling bleeding. The aim of this study is to evaluate the usefulness, efficacy, and safety of REBOA in puerperal bleeding due to abnormalities of placental implantation.</p></div><div><h3>Material and methods</h3><p>Between November 2019 and November 2021, our interventional radiology team placed six REBOA devices in six women scheduled for cesarean section due to placenta accrete. Results Mean blood loss during cesarean section after REBOA (3507.5<!--> <!-->mL) was similar to the amounts reported for other aortic balloons. The mean number of units of packed red blood cells required for transfusion was 3.5. Using REBOA provided the surgical team with adequate conditions to perform the surgery. There were no complications derived from REBOA, and the mean ICU stay was &lt; 2 days. Conclusion The technical characteristics of the REBOA device make it a safe and useful alternative for controlling massive bleeding in patients with placenta accreta.</p></div>","PeriodicalId":31509,"journal":{"name":"RADIOLOGIA","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RADIOLOGIA","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0033833822001382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims

: Abnormalities of placental implantation, which make up the spectrum of placenta accreta, are associated with high maternal morbidity and mortality due to massive bleeding during delivery. Placing aortic occlusion balloons helps control the bleeding, facilitating surgical intervention. A new device, resuscitative endovascular balloon occlusion of the aorta (REBOA), minimizes the risks and complications associated with the placement of traditional aortic balloons and is also efficacious in controlling bleeding. The aim of this study is to evaluate the usefulness, efficacy, and safety of REBOA in puerperal bleeding due to abnormalities of placental implantation.

Material and methods

Between November 2019 and November 2021, our interventional radiology team placed six REBOA devices in six women scheduled for cesarean section due to placenta accrete. Results Mean blood loss during cesarean section after REBOA (3507.5 mL) was similar to the amounts reported for other aortic balloons. The mean number of units of packed red blood cells required for transfusion was 3.5. Using REBOA provided the surgical team with adequate conditions to perform the surgery. There were no complications derived from REBOA, and the mean ICU stay was < 2 days. Conclusion The technical characteristics of the REBOA device make it a safe and useful alternative for controlling massive bleeding in patients with placenta accreta.

REBOA球囊主动脉闭塞在胎盘植入异常患者产后出血控制中的应用
背景和目的:胎盘植入异常是胎盘植入的一个组成部分,与分娩过程中大量出血导致的孕产妇高发病率和死亡率有关。放置主动脉阻断球囊有助于控制出血,便于手术干预。一种新的装置,复苏性主动脉腔内球囊闭塞(REBOA),最大限度地减少了与放置传统主动脉球囊相关的风险和并发症,并且在控制出血方面也很有效。本研究的目的是评估REBOA治疗胎盘植入异常引起的产后出血的有效性、有效性和安全性。材料和方法在2019年11月至2021年11月期间,我们的介入放射学团队为6名因胎盘植入而计划剖宫产的女性放置了6个REBOA装置。结果REBOA术后剖宫产期间的平均失血量(3507.5 mL)与其他主动脉球囊的报告量相似。输血所需的包装红细胞的平均单位数为3.5。使用REBOA为手术团队提供了进行手术的充分条件。没有来自REBOA的并发症,并且平均ICU停留时间<;2天。结论REBOA装置的技术特点使其成为控制植入胎盘患者大出血的安全有效的替代装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
RADIOLOGIA
RADIOLOGIA RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.60
自引率
7.70%
发文量
105
审稿时长
52 days
期刊介绍: La mejor revista para conocer de primera mano los originales más relevantes en la especialidad y las revisiones, casos y notas clínicas de mayor interés profesional. Además es la Publicación Oficial de la Sociedad Española de Radiología Médica.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信