Condensation Method for Humidity Measurement in the UMR Cloud Simulation Chamber

D. Hagen, D. R. White, D. J. Alofs
{"title":"Condensation Method for Humidity Measurement in the UMR Cloud Simulation Chamber","authors":"D. Hagen, D. R. White, D. J. Alofs","doi":"10.6028/jres.093.147","DOIUrl":null,"url":null,"abstract":"The University of Missouri-Rolla has developed a cloud simulation facility for the study of various atmospheric cloud processes. The initial relative humidity of the air sample put into the cloud chamber is a key parameter in virtually any experiment and needs to be known accurately. This report describes how the cloud simulation chamber itself has been used as a condensation type hygrometer to calibrate the system’s humidifier. Two distinct and physically different methods for inferring mixing ratio are used, one exploiting the sensitivity of aerosol activation to humidity, and the other exploiting the sensitivity of the rate of growth of cloud droplets to humidity. The two methods give agreement with each other to within a precision of one part per thousand in mixing ratio.","PeriodicalId":17082,"journal":{"name":"Journal of research of the National Bureau of Standards","volume":"19 1","pages":"551 - 556"},"PeriodicalIF":0.0000,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of research of the National Bureau of Standards","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.093.147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The University of Missouri-Rolla has developed a cloud simulation facility for the study of various atmospheric cloud processes. The initial relative humidity of the air sample put into the cloud chamber is a key parameter in virtually any experiment and needs to be known accurately. This report describes how the cloud simulation chamber itself has been used as a condensation type hygrometer to calibrate the system’s humidifier. Two distinct and physically different methods for inferring mixing ratio are used, one exploiting the sensitivity of aerosol activation to humidity, and the other exploiting the sensitivity of the rate of growth of cloud droplets to humidity. The two methods give agreement with each other to within a precision of one part per thousand in mixing ratio.
UMR云模拟室湿度测量的冷凝法
密苏里大学罗拉分校开发了一种云模拟设备,用于研究各种大气云过程。进入云室的空气样品的初始相对湿度在几乎任何实验中都是一个关键参数,需要准确地知道。本报告描述了如何将云模拟室本身用作冷凝式湿度计来校准系统的加湿器。使用了两种截然不同的物理上不同的方法来推断混合比,一种是利用气溶胶活化对湿度的敏感性,另一种是利用云滴生长速度对湿度的敏感性。这两种方法在混合比精度上的一致性都在千分之一以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信