Optimization of coagulation-flocculation parameters using a photometric dispersion analyser

Q2 Engineering
S. Ramphal, M. Sibiya
{"title":"Optimization of coagulation-flocculation parameters using a photometric dispersion analyser","authors":"S. Ramphal, M. Sibiya","doi":"10.5194/DWES-7-73-2014","DOIUrl":null,"url":null,"abstract":"Abstract. The size and structural characteristics of floc particles are important design and control parameters in water treatment and should be rapidly monitored with a reasonable amount of accuracy. In this study, a photometric dispersion analyser (PDA) coupled to standard jar test experiments was used to optimize coagulation-flocculation parameters while monitoring floc size and structure as well as the rate of floc formation during coagulation using alum. The optimal coagulation conditions were as follows: sample pH 8; alum dosage, 3 mg L−1 as Al3+; G value, 172 s−1; rapid mixing time, 20 s. These conditions resulted in unstable treated water having a calcium carbonate precipitation potential (CCPP) of −15 mg L−1 as CaCO3 and required a slaked lime dosage of 17 mg L−1 as CaCO3 to equilibrate CCPP to acceptable levels. PDA data revealed that aggregation rate and steady-state variance are primary parameters as both have substantial influence on coagulation-flocculation efficiency. However, the average steady state ratio, although an important parameter, had a lessened impact on coagulation-flocculation efficiency. The results of this study showed that the PDA instrument is an important tool in coagulation kinetic studies and can be employed as an additional tool in the optimization of coagulation conditions.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"7 1","pages":"73-82"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5194/DWES-7-73-2014","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drinking Water Engineering and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/DWES-7-73-2014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 18

Abstract

Abstract. The size and structural characteristics of floc particles are important design and control parameters in water treatment and should be rapidly monitored with a reasonable amount of accuracy. In this study, a photometric dispersion analyser (PDA) coupled to standard jar test experiments was used to optimize coagulation-flocculation parameters while monitoring floc size and structure as well as the rate of floc formation during coagulation using alum. The optimal coagulation conditions were as follows: sample pH 8; alum dosage, 3 mg L−1 as Al3+; G value, 172 s−1; rapid mixing time, 20 s. These conditions resulted in unstable treated water having a calcium carbonate precipitation potential (CCPP) of −15 mg L−1 as CaCO3 and required a slaked lime dosage of 17 mg L−1 as CaCO3 to equilibrate CCPP to acceptable levels. PDA data revealed that aggregation rate and steady-state variance are primary parameters as both have substantial influence on coagulation-flocculation efficiency. However, the average steady state ratio, although an important parameter, had a lessened impact on coagulation-flocculation efficiency. The results of this study showed that the PDA instrument is an important tool in coagulation kinetic studies and can be employed as an additional tool in the optimization of coagulation conditions.
用光度分散仪优化混凝-絮凝参数
摘要絮凝体颗粒的大小和结构特征是水处理中重要的设计和控制参数,应快速监测并保持合理的精度。在本研究中,采用光度分散分析仪(PDA)与标准罐试验相结合的方法,优化了混凝-絮凝参数,同时监测了明矾絮凝过程中絮凝体的大小和结构以及絮凝体的形成速度。最佳混凝条件为:样品pH为8;明矾用量,3mg L−1为Al3+;G值,172 s−1;快速搅拌时间,20秒。这些条件导致处理后的水不稳定,其碳酸钙沉淀电位(CCPP)为- 15 mg L−1作为CaCO3,需要17 mg L−1的石灰剂量作为CaCO3来平衡CCPP至可接受的水平。PDA数据显示,聚合速率和稳态方差是影响混凝效率的主要参数。平均稳态比虽然是一个重要的参数,但对混凝效率的影响较小。本研究结果表明,PDA仪器是凝血动力学研究的重要工具,可以作为凝血条件优化的附加工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drinking Water Engineering and Science
Drinking Water Engineering and Science Environmental Science-Water Science and Technology
CiteScore
3.90
自引率
0.00%
发文量
3
审稿时长
40 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信