Jorge Santiago Amaya, Cristhian Alejandro Romero González, Kevin Alexis Aguilar Bailon
{"title":"Web Control System for Transcorneal Electric Stimulation Devices","authors":"Jorge Santiago Amaya, Cristhian Alejandro Romero González, Kevin Alexis Aguilar Bailon","doi":"10.4236/jbise.2021.1412039","DOIUrl":null,"url":null,"abstract":"The electrical stimulation systems dedicated to generating unconventional waveforms have been shown to have a positive effect in the treatment of channelopathies, for example, in open-angle glaucoma. However, these signals can be distorted due to different external circumstances, which could lead to counterproductive effects in treatments such as increased intraocular pressure IOP or other effects that are unknown due to poor electrical signaling. In the present work, a web control system capable of communicating with transcorneal electrical stimulation equipment is proposed for the remote control of treatments applied to patients suffering from various ocular channelopathies. As the first phase of this system, it will only focus on treating patients with open-angle glaucoma since this disease is characterized by an increase in IOP and can be immediately measured by an ophthalmologist.","PeriodicalId":64231,"journal":{"name":"生物医学工程(英文)","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物医学工程(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.4236/jbise.2021.1412039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The electrical stimulation systems dedicated to generating unconventional waveforms have been shown to have a positive effect in the treatment of channelopathies, for example, in open-angle glaucoma. However, these signals can be distorted due to different external circumstances, which could lead to counterproductive effects in treatments such as increased intraocular pressure IOP or other effects that are unknown due to poor electrical signaling. In the present work, a web control system capable of communicating with transcorneal electrical stimulation equipment is proposed for the remote control of treatments applied to patients suffering from various ocular channelopathies. As the first phase of this system, it will only focus on treating patients with open-angle glaucoma since this disease is characterized by an increase in IOP and can be immediately measured by an ophthalmologist.