{"title":"Evaluation of surface dose calculations using monaco treatment planning system in an indigenously developed head and neck phantom","authors":"Mamta Mahur, Munendra Singh, M. Semwal, O. Gurjar","doi":"10.4103/mjdrdypu.mjdrdypu_827_21","DOIUrl":null,"url":null,"abstract":"Objective: The objective of this study is to evaluate the surface doses for 3-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) treatment planning techniques using an inhouse designed head and neck (HN) phantom and to compare the measured surface doses with the doses calculated using the Monaco treatment planning system (TPS). Materials and Methods: An arbitrary clinical target volume was defined with 5 mm planning target volume (PTV) expansion on computed tomography images of an in house designed heterogeneous HN phantom. 3DCRT, IMRT, and VMAT plans were created using Monaco TPS for prescribed dose of 60Gy in 30 fractions to cover 95% of PTV volume. Dose measurements were performed using EBT3 Gafchromic films at 10 selected points on the surface of HN phantom, especially inside the treatment area. Percentage mean dose differences were evaluated between the TPS calculated doses and measured dose values at these identified points. Results: The average dose difference between the TPS calculated doses and film measurements were found to be varying from 11.66% to 19.73%. It was observed that TPS overestimated the surface doses in comparison to measured doses. The results also shows that Gafchromic films can be used for surface dose measurements in patients for in vivo dosimetry in areas where high skin dose is expected during radiotherapy treatment. Conclusion: The limitations of TPS should be considered while evaluating surface doses in radiotherapy plans.","PeriodicalId":18412,"journal":{"name":"Medical Journal of Dr. D.Y. Patil Vidyapeeth","volume":"1 1","pages":"777 - 783"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of Dr. D.Y. Patil Vidyapeeth","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/mjdrdypu.mjdrdypu_827_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: The objective of this study is to evaluate the surface doses for 3-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) treatment planning techniques using an inhouse designed head and neck (HN) phantom and to compare the measured surface doses with the doses calculated using the Monaco treatment planning system (TPS). Materials and Methods: An arbitrary clinical target volume was defined with 5 mm planning target volume (PTV) expansion on computed tomography images of an in house designed heterogeneous HN phantom. 3DCRT, IMRT, and VMAT plans were created using Monaco TPS for prescribed dose of 60Gy in 30 fractions to cover 95% of PTV volume. Dose measurements were performed using EBT3 Gafchromic films at 10 selected points on the surface of HN phantom, especially inside the treatment area. Percentage mean dose differences were evaluated between the TPS calculated doses and measured dose values at these identified points. Results: The average dose difference between the TPS calculated doses and film measurements were found to be varying from 11.66% to 19.73%. It was observed that TPS overestimated the surface doses in comparison to measured doses. The results also shows that Gafchromic films can be used for surface dose measurements in patients for in vivo dosimetry in areas where high skin dose is expected during radiotherapy treatment. Conclusion: The limitations of TPS should be considered while evaluating surface doses in radiotherapy plans.
评估使用摩纳哥治疗计划系统的表面剂量计算在本土开发的头颈部幻影
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
221
审稿时长
43 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信