Reference PMHS Sled Tests to Assess Submarining.

Q2 Medicine
J. Uriot, P. Potier, P. Baudrit, X. Trosseille, P. Petit, Olivier Richard, S. Compigne, M. Masuda, R. Douard
{"title":"Reference PMHS Sled Tests to Assess Submarining.","authors":"J. Uriot, P. Potier, P. Baudrit, X. Trosseille, P. Petit, Olivier Richard, S. Compigne, M. Masuda, R. Douard","doi":"10.4271/2015-22-0008","DOIUrl":null,"url":null,"abstract":"Sled tests focused on pelvis behavior and submarining can be found in the literature. However, they were performed either with rigid seats or with commercial seats. The objective of this study was to get reference tests to assess the submarining ability of dummies in more realistic conditions than on rigid seat, but still in a repeatable and reproducible setup. For this purpose, a semi-rigid seat was developed, which mimics the behavior of real seats, although it is made of rigid plates and springs that are easy to reproduce and simulate with an FE model. In total, eight PMHS sled tests were performed on this semirigid seat to get data in two different configurations: first in a front seat configuration that was designed to prevent submarining, then in a rear seat configuration with adjusted spring stiffness to generate submarining. All subjects sustained extensive rib fractures from the shoulder belt loading. No pelvis fractures and no submarining were observed in the front seat configuration, but two subjects sustained lumbar vertebrae fractures. In the rear seat configuration, all subjects sustained pelvic fractures and demonstrated submarining. Corridors were constructed for the external forces and the PMHS kinematics. They are provided in this paper as new reference tests to assess the biofidelity of human surrogates in different configurations that either result in submarining or do not. In future, it is intended to analyze further seat and restraint system configurations to be able to define a submarining predictor.","PeriodicalId":35289,"journal":{"name":"Stapp car crash journal","volume":"40 1","pages":"203-23"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stapp car crash journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4271/2015-22-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 20

Abstract

Sled tests focused on pelvis behavior and submarining can be found in the literature. However, they were performed either with rigid seats or with commercial seats. The objective of this study was to get reference tests to assess the submarining ability of dummies in more realistic conditions than on rigid seat, but still in a repeatable and reproducible setup. For this purpose, a semi-rigid seat was developed, which mimics the behavior of real seats, although it is made of rigid plates and springs that are easy to reproduce and simulate with an FE model. In total, eight PMHS sled tests were performed on this semirigid seat to get data in two different configurations: first in a front seat configuration that was designed to prevent submarining, then in a rear seat configuration with adjusted spring stiffness to generate submarining. All subjects sustained extensive rib fractures from the shoulder belt loading. No pelvis fractures and no submarining were observed in the front seat configuration, but two subjects sustained lumbar vertebrae fractures. In the rear seat configuration, all subjects sustained pelvic fractures and demonstrated submarining. Corridors were constructed for the external forces and the PMHS kinematics. They are provided in this paper as new reference tests to assess the biofidelity of human surrogates in different configurations that either result in submarining or do not. In future, it is intended to analyze further seat and restraint system configurations to be able to define a submarining predictor.
参考PMHS滑车试验评估潜艇。
雪橇试验侧重于骨盆行为和潜行可以在文献中找到。然而,它们要么使用刚性座椅,要么使用商用座椅。本研究的目的是获得参考试验,以评估假人在更真实的条件下的潜水能力,而不是在刚性座椅上,但仍然是在可重复和可重复的设置。为此,开发了一种半刚性座椅,它模仿了真实座椅的行为,尽管它是由刚性板和弹簧制成的,易于用有限元模型复制和模拟。在这种半刚性座椅上,共进行了8次PMHS滑橇测试,以获得两种不同配置下的数据:首先是设计用于防止潜沉的前座椅配置,然后是调整了弹簧刚度以产生潜沉的后排座椅配置。所有受试者均因肩带负荷而出现大面积肋骨骨折。前座组未见骨盆骨折和水下塌陷,但有两名受试者腰椎骨折。在后排座位组中,所有受试者都出现骨盆骨折并表现出下沉。构建了用于外部作用力和PMHS运动学的廊道。本文提供了它们作为新的参考测试,以评估不同配置下的人类替代品的生物保真度,这些配置可能导致或不导致潜水。在未来,它打算进一步分析座椅和约束系统配置,以便能够定义一个潜艇预测器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Stapp car crash journal
Stapp car crash journal Medicine-Medicine (all)
CiteScore
3.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信