Abdul Rafiq Khan, A. Alothaim, W. Tamimi, Majid Alshaibani, Souad Marwan Al Enazi, S. Saad, K. M. Khan
{"title":"Simple Quantitation of Flucytosine in Low Volume Serum Samples and Evaluation of Common Endogenous Interferences by HPLC-UV","authors":"Abdul Rafiq Khan, A. Alothaim, W. Tamimi, Majid Alshaibani, Souad Marwan Al Enazi, S. Saad, K. M. Khan","doi":"10.4236/ajac.2022.139020","DOIUrl":null,"url":null,"abstract":"5-Fluorocytosine (5-FC) is used for the treatment of several infections. It is extremely important to monitor blood level concentration for maximum ac-tivity to avoid its side effects. A simple, faster, and more accurate analytical method is developed and validated using high-performance liquid chromatography with UV detection in a very low-volume serum sample. Exactly 50 µL of serum was precipitated with 5% trichloroacetic acid. After mixing and centrifugation, 20 µL of supernatant was injected into the HPLC column. Detection was performed at 280 nm. The method is very specific and free from interfering substances due to different drugs and their different circulating metabolites. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.50 μg/L and 1.0 μg/L, respectively. The method was linear in the range of 5 - 150 μg/L in the serum sample. In method comparison, the correlation coefficient r 2 was 0.999 and the percentage recovery was 90% - 105% on four levels of the quality control samples. Within run and between run precision was found to be less than 2.2% at four different concentrations (5, 25, 50, and 100 μg/L). A simple, faster, and more accurate HPLC-UV method is developed which is very useful for monitoring 5-FC concentration in low volume serum samples without evaporation step and ion exchange chromatography within minutes.","PeriodicalId":63216,"journal":{"name":"美国分析化学(英文)","volume":"144 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"美国分析化学(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/ajac.2022.139020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
5-Fluorocytosine (5-FC) is used for the treatment of several infections. It is extremely important to monitor blood level concentration for maximum ac-tivity to avoid its side effects. A simple, faster, and more accurate analytical method is developed and validated using high-performance liquid chromatography with UV detection in a very low-volume serum sample. Exactly 50 µL of serum was precipitated with 5% trichloroacetic acid. After mixing and centrifugation, 20 µL of supernatant was injected into the HPLC column. Detection was performed at 280 nm. The method is very specific and free from interfering substances due to different drugs and their different circulating metabolites. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.50 μg/L and 1.0 μg/L, respectively. The method was linear in the range of 5 - 150 μg/L in the serum sample. In method comparison, the correlation coefficient r 2 was 0.999 and the percentage recovery was 90% - 105% on four levels of the quality control samples. Within run and between run precision was found to be less than 2.2% at four different concentrations (5, 25, 50, and 100 μg/L). A simple, faster, and more accurate HPLC-UV method is developed which is very useful for monitoring 5-FC concentration in low volume serum samples without evaporation step and ion exchange chromatography within minutes.