Junsu Lee, K. Lee, Hwanseong Jeong, Dong J. Kim, Jung Hwan Lee, Minsik Jo
{"title":"A Study of the Fiber Fuse in Single-mode 2-kW-class High-power Fiber Amplifiers","authors":"Junsu Lee, K. Lee, Hwanseong Jeong, Dong J. Kim, Jung Hwan Lee, Minsik Jo","doi":"10.3807/KJOP.2020.31.1.007","DOIUrl":null,"url":null,"abstract":"In this paper, we experimentally investigate the fiber fuse in single-mode 2-kW-class high-power fiber amplifiers, depending on the cooling method at the splicing point. We measured the temperature of the splicing point between the pump-signal combiner and gain fiber as a function of laser output power. The temperature of the splicing point increased from 20 to 32°C with a slope of 0.01°C/W, up to 1.2 kW of laser output power. At higher powers the temperature of the splicing point increased dramatically, with a slope of 0.08°C/W. After that, the fiber amplifier was destroyed during operation at 1.96 kW of output power by fiber fuse. The bullet shape, a common feature of fiber fuse, was observed in the damaged passive fiber core of the pump-signal combiner. Later, we adopted an improved water-cooled cold plate to increase the cooling efficiency at the splicing point, and investigated the laser output power. The temperature at the splicing point was 35.8°C with a temperature-rise slope of 0.007°C/W at the maximum output power of 2.05 kW. The beam quality M2 was measured to be less than 1.3, and the output beam’s profile was a stable Gaussian shape. Finally, neither fiber fuse nor mode instability was observed in the fiber amplifier at the maximum output power of 2.05 kW.","PeriodicalId":42467,"journal":{"name":"Korean Journal of Optics and Photonics","volume":"31 1","pages":"7-12"},"PeriodicalIF":0.1000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Optics and Photonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3807/KJOP.2020.31.1.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 1
Abstract
In this paper, we experimentally investigate the fiber fuse in single-mode 2-kW-class high-power fiber amplifiers, depending on the cooling method at the splicing point. We measured the temperature of the splicing point between the pump-signal combiner and gain fiber as a function of laser output power. The temperature of the splicing point increased from 20 to 32°C with a slope of 0.01°C/W, up to 1.2 kW of laser output power. At higher powers the temperature of the splicing point increased dramatically, with a slope of 0.08°C/W. After that, the fiber amplifier was destroyed during operation at 1.96 kW of output power by fiber fuse. The bullet shape, a common feature of fiber fuse, was observed in the damaged passive fiber core of the pump-signal combiner. Later, we adopted an improved water-cooled cold plate to increase the cooling efficiency at the splicing point, and investigated the laser output power. The temperature at the splicing point was 35.8°C with a temperature-rise slope of 0.007°C/W at the maximum output power of 2.05 kW. The beam quality M2 was measured to be less than 1.3, and the output beam’s profile was a stable Gaussian shape. Finally, neither fiber fuse nor mode instability was observed in the fiber amplifier at the maximum output power of 2.05 kW.