Intra- and inter-individual variability of strain during uncompensable heat stress determined from a longitudinal study

B. Kampmann, G. Bresser, M. Schütte
{"title":"Intra- and inter-individual variability of strain during uncompensable heat stress determined from a longitudinal study","authors":"B. Kampmann, G. Bresser, M. Schütte","doi":"10.3233/OER-2009-0169","DOIUrl":null,"url":null,"abstract":"Four mine rescue brigadesmen performed three different standardized trainings in uncompensable heat stress with different equipment, clothing and climatic stress. The strain during these trainings may be considered as typical for training and missions of firemen, mine rescue brigadesmen and subjects working under protective clothing. - During ten years the diverse trainings were repeated. Heart rates and body temperatures were recorded throughout the exposures. A significant linear trend over time only was found for body mass (increase in three of the subjects). Specific physical fitness (fitness per body mass) as well as heart rate or body temperature showed no significant trend over time for initial or final values. The variability of the physiological strain is described in good approximation by normal distributions and shows quite a high magnitude. On base of the whole data set inter-individual components of variance are estimated by a 2-factorial ANOVA (person, time of measurement) with the factor time of measurement nested under the factor person. Confidence intervals for the estimated mean values and respectively, the calculation of the required number of measurements for a given confidence interval are determined by performing a two factorial ANOVA with both factors fully crossed.","PeriodicalId":91780,"journal":{"name":"Occupational ergonomics : the journal of the International Society for Occupational Ergonomics and Safety","volume":"8 1","pages":"171-183"},"PeriodicalIF":0.0000,"publicationDate":"2009-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/OER-2009-0169","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Occupational ergonomics : the journal of the International Society for Occupational Ergonomics and Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/OER-2009-0169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Four mine rescue brigadesmen performed three different standardized trainings in uncompensable heat stress with different equipment, clothing and climatic stress. The strain during these trainings may be considered as typical for training and missions of firemen, mine rescue brigadesmen and subjects working under protective clothing. - During ten years the diverse trainings were repeated. Heart rates and body temperatures were recorded throughout the exposures. A significant linear trend over time only was found for body mass (increase in three of the subjects). Specific physical fitness (fitness per body mass) as well as heart rate or body temperature showed no significant trend over time for initial or final values. The variability of the physiological strain is described in good approximation by normal distributions and shows quite a high magnitude. On base of the whole data set inter-individual components of variance are estimated by a 2-factorial ANOVA (person, time of measurement) with the factor time of measurement nested under the factor person. Confidence intervals for the estimated mean values and respectively, the calculation of the required number of measurements for a given confidence interval are determined by performing a two factorial ANOVA with both factors fully crossed.
从一项纵向研究确定的不可补偿热应力期间个体内部和个体之间的应变变异性
四名矿山救援旅队员在不同的装备、服装和气候条件下进行了三种不同的不可补偿热应激标准化训练。这些训练期间的应变可被认为是消防员、矿山救援队和穿着防护服工作的人员的训练和任务的典型。-在十年期间,重复进行了各种培训。在整个暴露过程中记录心率和体温。随着时间的推移,只有体重呈显著的线性趋势(其中3名受试者体重增加)。特定体能(每体重的体能)以及心率或体温在初始值或最终值上没有随时间的显著趋势。生理应变的变异性可以用正态分布很好地近似描述,并显示出相当高的幅度。在整个数据集的基础上,通过2因子方差分析(人,测量时间)估计个体间方差成分,测量时间嵌套在因素人之下。估计平均值的置信区间,以及给定置信区间所需测量数的计算,通过两个因素完全交叉的两因子方差分析来确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信